Performance Chart; Calculate Fluid Outlet Pressure (Black Curves); Calculate Pump Air Consumption (Gray Curves) - Graco T2 Instructions Manual

2:1 ratio transfer pump
Hide thumbs Also See for T2:
Table of Contents

Advertisement

Performance Chart

Performance Chart
Calculate Fluid Outlet Pressure
(black curves)
To calculate fluid outlet pressure (MPa/bar/psi) at a
specific fluid flow (lpm/gpm) and operating air pressure
(MPa/bar/psi), use the following instructions and pump
data chart.
1. Locate desired fluid flow along bottom of chart.
2. Follow vertical line up to intersection with selected
air pressure curve (black). Follow horizontally left to
read fluid outlet pressure.
Key: Air Pressure
A
180 psi (1.2 MPa, 12.4 bar)
B
100 psi (0.7 MPa, 7 bar)
C
70 psi (0.5 MPa, 4.8 bar)
D
40 psi (0.3 MPa, 2.8 bar)
26
Calculate Pump Air
Consumption (gray curves)
To calculate pump air consumption (m
a specific fluid flow (lpm/gpm) and air pressure
(MPa/bar/psi), use the following instructions and pump
data chart.
1. Locate desired fluid flow along bottom of chart.
2. Follow vertical line up to intersection with selected
air pressure curve (gray). Follow horizontally right to
read air consumption.
500
(3.5, 34.5)
400
(2.8, 28)
A
300
(2.1, 21)
B
200
(1.4,14)
C
100
D
(0.7, 7)
0.0
0.0
0.5
1.0
(1.9)
(3.8)
D
1.5
2.0
2.5
3.0
3.5
(5.7)
(7.6)
(9.5)
(11.4)
(13.3)
Fluid Flow in gpm (lpm)
3
/min or scfm) at
40.00
(1.1)
35.00
(1.0)
30.00
(0.8)
25.00
(0.7)
20.00
(0.6)
A
15.00
(0.4)
B
10.00
(0.3)
C
5.00
(0.1)
0.00
4.0
4.5
(15.2)
(17.1)
311882U