Technical Specifications - Graco T2 Instructions Manual

2:1 ratio transfer pump
Hide thumbs Also See for T2:
Table of Contents

Advertisement

Technical Specifications

T2, 2:1 Ratio Transfer Pump
Pressure ratio
Maximum fluid working pressure
Maximum air inlet pressure
Maximum continuous outlet flow
Maximum intermittent outlet flow
Pump cycles per 1 gallon (3.8 liters)
Maximum recommended pump speed for con-
tinuous operation
Gallons (liters) per pump cycle
Maximum ambient operating temperature
Maximum fluid temperature
Inlet/Outlet Sizes
Air inlet size
Fluid outlet size
Materials of Construction
Wetted materials
Weight
All models
Noise (dBa)
Maximum sound pressure*
Maximum sound power**
*Sound pressure measured 3.28 feet (1 meter) from equipment.
**Sound power measured per ISO-9614-2.
311882U
US
405 psi
180 psi
5 gpm
7.5 gpm
100 cpm (150 cpm intermittent)
0.034 gpm
120°F
190°F
Stainless steel, PTFE
21 lb.
88.7 dB(A) at 80 psi (.55 MPa, 5.5 bar)
96.8 dB(A) at 80 psi (.55 MPa, 5.5 bar)
Technical Specifications
Metric
2.25:1
2.8 MPa, 28 bar
1.2 MPa, 12 bar
20 lpm
28 lpm
15.9
0.128 lpm
49°C
88°C
1/4 npt(f)
3/4 npt (f)
9.5 kg
29