Technibel CHGF Series Technical Instructions page 9

Air to water heat pump and chiller
Table of Contents

Advertisement

PhrF model
Power supply
Cooling capacity (EN 14511)
EER (EN 14511)
Cold power consumption (EN 14511)
Heating capacity (EN 14511)
COP (EN 14511)
Hot power consumption (EN 14511)
Maximum power consumption
Maximum input current
Starting current ****
Number of compressors / circuit
Refrigerant charge
Low / high pressure switch
Number of axial fans
Air flow rate
Water flow rate, cold only
Heat pump water flow rate
Diameter of hydraulic couplings
Water headloss (cold only)
Water headloss (heating)
Pressure head available (cold only)
Pressure head available (heating)
Water capacity excluding option
Expansion vessel
Tank capacity
Height
Length
Depth
Sound power
Sound pressure at 10 metres
Weight packed *
Net weight (excluding packaging) *
Minimum water capacity of system **
Maximum water capacity of system ***
(*)
Weight for model with pump and tank.
(**)
If the water volume of the system is below the minimum, a buffer tank must be installed.
(***) If the water volume of the system is above the maximum, an additional expansion vessel is required.
(****) Starting current accounting for the electronic starter (current limiter).
- Cooling capacity: outside air temperature 35°C, water temperature 12°C - 7°C.
- Heating capacity: outside air temperature 7°C (dry bulb) and 6.2°C (wet bulb) water temperature 40°C - 45°C.
- Sound pressure level measured in compliance with the standards ISO 3741 - ISO 3744 and EN 29614-1
- Sound pressure measured at a distance of 10 metres and 1.5 metres from the ground in free field conditions (fan end).
- The maximum power consumption is the power consumption of the mains power supply required for the unit to operate.
- The maximum input current is the current level at which the internal protective devices of the unit are tripped. It is the maximum
allowable current per unit. This value must never be exceeded and must be used to size the line.
23
27
V-Ph-Hz
kW
19.55
23.68
2.61
2.83
kW
7.49
8.38
kW
22.57
26.83
3
3.2
kW
7.52
8.38
kW
13.60
14.50
A
21.7
24
A
68
103
1 / 1
1 / 1
kg
4.23
5.80
bar 2 / 42
2 / 42
4
4
3
m
/h
9,990
9,307
L/h
3,373
4,094
L/h
3,949
4,670
Inch
1.25
1.25
kPa
51
49
kPa
69
62
kPa
123
116
kPa
97
95
Litres
4
4
Litres
5
5
Litres
50
50
mm
1,300
1,300
mm
1,565
1,565
mm
600
600
dB(A)
71
72
dB(A)
43
44
kg
283
295
kg
268
280
Litres
105
125
Litres
145
145
9
32
40
46
400-3N-50
27.99
34.84
39.46
3.09
2.94
3
9.06
11.86
13.14
30.80
38.67
44.07
3.24
3.23
3.27
9.52
11.97
13.47
18.30
21.80
22.40
28.6
35.2
36.4
87
108
108
1 / 1
1 / 1
1 / 1
7.50
7.80
10.80
2 / 42
2 / 42
2 / 42
2
2
2
16,276
16,276
15,776
4,833
6,021
6,823
5,396
6,756
7,769
1.25
1.25
1.25
40
41
43
49
50
54
143
130
119
128
113
99
5.5
5.5
5.5
8
8
8
125
125
125
1,485
1,485
1,485
1,990
1,990
1,990
950
950
950
73
73
75
45
45
47
406
466
495
384
444
473
140
175
205
231
231
231
60
77
85
54.27
69.25
75.41
2.89
2.88
2.7
18.8
24.05
27.93
59.12
75.67
83.97
3.11
3.17
3.08
18.98
23.87
27.23
27
32.30
39.40
48
57
69
117
136
154
2 / 1
2 / 1
2 / 1
12.80
16.30
16.30
2 / 42
2 / 42
2 / 42
4
4
4
24,930
24,354
24,354
9,202
11,782
12,831
10,303
13,244
14,579
2
2
2
56
55
64
60
59
71
138
128
114
130
110
100
7
11
12
8
8
8
125
125
125
1,735
1,735
1,735
2,091
2,091
2,091
1,183
1,183
1,183
81
81
81
53
53
53
660
702
792
648
690
780
270
345
380
231
231
231