Do the following to connect the MAINS power to the CAP H.
Follow the steps in
1
Locate the MAINS power cable that was delivered with the CAP H (shown in
2
Locate or install a suitable power junction box or receptacle near the CAP H, and then route the power
3
cable from the power source to the CAP H.
Do not connect the cable to the CAP H MAINS connector at this time. The power source must be
interruptible.
Secure the MAINS cable per local regulations and electrical codes. Allow enough slack in the cable at the
4
CAP H to plug or unplug the cable into the CAP H MAINS connector.
Wire the power cable to the junction box or receptacle. Refer to the color code and pin numbers shown in
5
Figure 7 on page
With the cable's MAINS plug disconnected from the CAP H, turn the circuit breaker on, unscrew the plug's
6
protective cover, and carefully test the plug with a voltmeter to ensure that the voltage and polarity are
correct.
Once the testing has been completed, turn off the circuit breaker.
7
Unscrew the protective cover from the MAINS connector of the CAP H (see
8
Insert the plug into the MAINS connector and tighten the clamping ring until it is hand tight. Do not
9
over-tighten the clamping ring.
10 Turn on the circuit breaker.
The CAP H is powered on as soon as power is connected to it.
M0201AKB_uc
© January 2019 CommScope, Inc.
"Ground the CAP H" on page
42.
CommScope Era
32.
High Power Carrier Access Point Installation Guide — Preliminary
Installing a CAP H
Figure 7 on page
42).
Figure 7 on page
42).
Page 43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents