Failure Code [Dafgmc] Gps Module Error - Komatsu PC130-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC130-8:
Table of Contents

Advertisement

SEN04121-02

Failure code [DAFGMC] GPS module error

User code
Failure code
DAFGMC
Contents of
• Position data is not sent from GPS module (in machine monitor) to KOMTRAX communication
trouble
MODEM in 50 seconds after KOMTRAX is started.
Action of
• None in particular.
machine monitor
• If cause of failure disappears, system resets itself.
Problem that
appears on
machine
Related
• Method of reproducing failure code: Turn starting switch ON (At least 50 seconds after starting
information
switch is turned ON).
Possible causes
and standard
value in normal
1 Defective machine monitor
state
8
GPS module operation error
Trouble
(KOMTRAX system in machine monitor)
Cause
Standard value in normal state/Remarks on troubleshooting
GPS module of machine monitor may be defective. (Since trouble
is in system, troubleshooting cannot be carried out.)
40 Troubleshooting
1
PC130-8