11. Remove duct (20).
12. Remove the mounting bolt of bracket (21), and
move it backward together with machine moni-
tor (22).
a The connector of the machine monitor
needs not to be disconnect .
28
50 Disassembly and assembly
13. Move harness (23) and disconnect connector
M05 (24).
14. Open cap (25) and remove nut (26) to remove
wiper arm (27).
15. Remove cap (28), nut (29), washer (30) and
packing (31).