Calibration (Ca); Display In Fahrenheit Or Centigrade Unit (Cf); Error Description; Sensor Fault Alarm - Inkbird IHC-230 User Manual

Plug-n-play humidity and temperature controller
Table of Contents

Advertisement

IHC-230 User Manual

5.5 Calibration (CA)

When there is deviation between measured value and actual value, the value can be
calibrated by setting the CA. The corrected value is equal to value before calibration plus
corrected value (corrected value could be positive value, 0 or negative value).

5.6 Display in Fahrenheit or Centigrade unit (CF)

Fahrenheit or Centigrade degree displaying can be selected as needed. Default displaying
is in Centigrade degree. Please set CF to F to change the displaying in Fahrenheit degree if
needed.
Attentions: After CF value changed, all the setting value will be recovered to factory
settings.

6. Error Description

Sensor Fault Alarm

: when sensor is being in short circuit or open loop, the controller
will initiate sensor fault mode by stopping all the operation with the buzzer alarming and
ER displaying. Buzzer alarming can be dismissed by pressing any key. And the controller
will return to normal working mode when the fault was removed.