Malfunction
No Power
Unit resets or pauses
randomly
Heart rate is displaying
erratically or not
displaying
Possible Cause
Unit turned off
Damaged power cord
Power cord not fully seated in socket
No power at outlet
Damaged power cord
Power cord not fully seated in socket
Safety e-stop key not fully engaged
Insufficient power
Error code is displayed on console
Pinched or loose main communication cable
Transmitter belt contacts are not making
good contact with the skin
Contacts on the transmitter belt are not
moist
Transmitter belt is not within 3 feet (1 meter)
of the heart rate receiver
The battery inside the transmitter belt is
depleted
Another user wearing a compatible
transmitter strap is within 3 foot (1 meter) of
the unit
Environmental interference from high
voltage power lines
Environmental interference from
computers or Wi-Fi router
Environmental interference from motor
driven appliances
Environmental interference from cell or
cordless phone
Truefitness.com / 800.426.6570 / 636.272.7100
Corrective Action
Verify the On/Off switch is at the ON position
Replace power cord
Inspect power connection at the unit and outlet
Using a voltmeter verify power at outlet
Replace power cord
Inspect power connection at the unit and outlet
Re-engage the safety/e-stop key to the console
Verify output voltage from 20A outlet with a
voltmeter
Contact TRUE Fitness Customer Service
Re-adjust the transmitter belt so that it is in full
contact with the skin
Moisten the contacts on the transmitter belt
Adjust your position on the belt so that you
are within 3 feet (1 meter) of the console
Replace the transmitter belt with a
compatible transmitter belt
Move the units so that there is more space
in-between units
Move the unit to another position
within the room or move the cause of
the interference until heart rate reading
are stable. If the probable source of
interference is plugged into the same outlet
move the suspect source to another outlet.