intensity IDCC090KF-5 Owner's Manual

intensity IDCC090KF-5 Owner's Manual

Commercial split system cooling only 220v 7.5-10 tons.
Hide thumbs Also See for IDCC090KF-5:

Advertisement

Quick Links

COMMERCIAL SPLIT SYSTEM
220V | 7.5 - 10 Tons.
COOLING ONLY
IDCC090KF-5, IDCE090KF-5,
IDCC120KF-5, IDCE120KF-5.
OWNER´S MANUAL
MAN-O-IDCSF/5-0618
intensity.mx

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IDCC090KF-5 and is the answer not in the manual?

Questions and answers

Summary of Contents for intensity IDCC090KF-5

  • Page 1 COMMERCIAL SPLIT SYSTEM 220V | 7.5 - 10 Tons. COOLING ONLY IDCC090KF-5, IDCE090KF-5, IDCC120KF-5, IDCE120KF-5. OWNER´S MANUAL MAN-O-IDCSF/5-0618 intensity.mx...
  • Page 2: Table Of Contents

    Use of wire or copper wire may cause the unit to break down or cause a fire. PRECAUTIONS.................1 It is not good for your health to expose your body to the ELECTRIC SAFETY REQUIREMENT..........2 air flow for a long time. FUNCTIONS &...
  • Page 3: Electric Safety Requirement

    Power supply If damaged, the unit may fall and result in injury. Model specification specification Outdoor unit IDCC090KF-5 208-230V 3Ph ~ 60Hz To avoid oxygen deficiency, ventilate the room Indoor unit IDCE090KF-5 220V 3Ph ~ 60Hz sufficiently if equipment with burner is used together with the air conditioner.
  • Page 4: Names And Functions Of Air Conditioner Components

    4 NAMES AND FUNCTIONS OF AIR Do not use or store flammable gases or liquids near the air conditioner, e.g., hair styling jelly, paint and gasoline. Otherwise, CONDITIONER COMPONENTS fire may occur. Do not touch the deflector plate while the air deflector works. IDCE090KF-5 Otherwise, the fingers may be clipped or the driving parts of the IDCE120KF-5...
  • Page 5: Beat Operation

    6 BEAT OPERATION If the indoor unit is installed in a place with heavy dust, clean the filter more often. If the stain is heavy and difficult to clean, replace the filter (the Pay attention to the following issues to ensure that the system is substitute filter is an optional assembly in the sale).
  • Page 6: Phenomena Not Attributable To Faults Of Air Conditioner

    8 PHENOMENA NOT ATTRIBUTABLE TO 1) Maintenance of fan : One week after the unit is running, the elastic belt should be FAULTS OF AIR CONDITIONER re-adjusted, and should be inspected once every three months in accordance with the requirements of inspection. The following phenomena do not indicate exception of air conditioner 2) Maintenance of belt and pulley :...
  • Page 7: Faults Of Air Conditioner And Cause

    In order to prevent frosting of the indoor heat exchanger, the air Detect leak, and fill the The refrigerant is conditioner shifts to the air supply mode automatically, and refrigerant of a correct excessive or resumes to cooling mode in a short time. quantity deficient.
  • Page 8: Faults Of Remote Controller And Cause

    10 FAULTS OF REMOTE CONTROLLER Table 10-5 AND CAUSE No sound of receiving signal Symptom cause Check item Before requesting for maintenance or repair, inspect the following: When the ON/OFF button When Align the signal Table 10-1 is pressed, check pressing the transmiting part of the whether the signal...
  • Page 9: Model, Specification & Parameters

    12 MODEL, SPECIFICATION & PARAMETERS In case any parameters in the following table are changed, no other notice will be given. The parameters specified on the nameplate shall prevail. NOTE The cooling capacity of the air conditioner is measured in a standard environment where the indoor dry/wet bulb temperature is 27°C/19°C and the outdoor dry/wet bulb temperature is 35°C/24°C;...