intensity IHWH-04KF-3 Owner's Manual

intensity IHWH-04KF-3 Owner's Manual

High wall chilled water

Advertisement

Quick Links

IHWH-04KF-3, IHWH-06KF-3
High Wall

Chilled Water

OWNER'S MANUAL
www.intensity.com.mx
MAN-O-IHWH-1112

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IHWH-04KF-3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for intensity IHWH-04KF-3

  • Page 1: Chilled Water

    IHWH-04KF-3, IHWH-06KF-3 High Wall Chilled Water OWNER’S MANUAL www.intensity.com.mx MAN-O-IHWH-1112...
  • Page 2: Drain Pipe

    Air inlet Air outlet Inlet pipe Return pipe Drain pipe Infrared signal Temperature receiver display Operation lamp Timer indicator Display panel Bottom plate Faceplate Display panel Horizontal air deflector Remote controller...
  • Page 3: Important Safety Information

    1. IMPORTANT SAFETY INFORMATION To prevent water leak, contact your dealer. When the system is installed and runs in a small room, it is required to keep the concentration of the water, if by any To prevent injury to the user or other people and property chance coming out, below the limit.
  • Page 4: Operation Range

    Failure to observe could cause the chemicals to become Open the faceplate,and you can find the temporary button on deposited in the unit, which could endanger the health of the display panel. (Refer to Fig 2-1) those who are hypersensitive to chemicals. This function is used to operate the unit temporarily in case you misplace the remote controller or its batteries are exhausted.
  • Page 5: Maintenance

    Adjust vertical air Adjust the air flow louver properly and avoid direct air flow to Open the horizontal air deflector,and then manually adjust room inhabitants. vertical air deflector. Adjust the room temperature properly for a comfortable environment. Avoid excessive heating or cooling. C faceplate Prevent direct sunlight during cooling operation by using curtains or blinds.
  • Page 6: Following Symptoms Are Not Air Conditioner Troubles

    Maintenance before a long stop period (eg. at the end of the season) S faceplate Let the indoor units run in fan only operation for about half a day in order to dry the interior of the units. Clean air filters and casings of indoor units. Refer to " Cleaning the air filter"...
  • Page 7: Troubleshooting

    Symptom 3: White mist comes out of a unit The unit can absorb the smell of rooms, furniture, cigarettes, etc., and then emit it again. Symptom 3.1: Indoor unit When humidity is high during cooling operation If the interior of Symptom 7: The outdoor unit fan does not spin.
  • Page 8 Table 8-2 Symptoms Causes Solution Check whether the MODE When the automatic mode is indicated on the display is selected, the air conditioner will "AUTO" automatically change the fan The fan speed can not be speed. changed. Protection against hot wind in Reduce the temperature of inlet in cooling mode.

This manual is also suitable for:

Ihwh-06kf-3

Table of Contents