6 BEAT OPERATION

Pay attention to the following issues to ensure that the system is
in normal operation. For detailed operation procedure, see the
corresponding instructions.
Adjust the air flow direction properly, and do not aim the air flow
at the persons in the room directly.
Adjust the room temperature properly to get a comfortable
environment. Avoid being too hot or too cold.
In the cooling operation, use curtains or window shades to
prevent direct sunlight.
Close all windows and doors. If the doors and windows are
open, the air in the room will flow out and the effect of
cooling/heating will be compromised.
Set the predetermined operation time through the remote
controller.
Do not put any objects near the air inlet or outlet which obstruct
air flow. Otherwise, it will reduce efficiency of the air conditioner
or even lead to system interruption.
Before leaving the unit idle for a long period, cut off the main
power switch, and remove the batteries in the remote controller.
When the main power switch is turned on, a certain extent of
electric power is consumed even if the air conditioner does not
run. Turning off the main power switch can save energy. Before
restart the unit, please connect the power supply advance 12
hours before restart the unit, for ensure the power the unit could
proform in normally.
Cleanse the air filter every another two weeks. The effect of
cooling or heating will be compromised if the air filter is blocked.
Please consign professional personnel to check, clean and
maintain the duct, drain system regularly.
7 MAINTENANCE & UPKEEP
7.1 Importants
Only the professionals can perform repair.
Before performing operation for the electric connectors or
cleansing the filter, turn off the main power switch.
Do not use water or air with a temperature higher than 50°C to
cleanse the filter or panel.
Check and maintain the ventilating slot once every half years,
wash and maintain with corresponding disinfection shall
process once
every two years are recommended. The filter can expel dust and
other particles in the air. If it is blocked, the effect of the air
conditioner will be degraded.Therefore, clean it every another
two weeks if you use the air conditioner for a long period.
owner's manual
4
NOTE
If the indoor unit is installed in a place with heavy dust, clean the
filter more often.
If the stain is heavy and difficult to clean, replace the filter (the
substitute filter is an optional assembly in the sale).
Do not replace the power cable without permission. If the power
cable is damaged, specialized power cable must be used as
substitute. No not repair the air conditioner without permission.
The foregoing operations must be performed by the local
distributor or aftersales service office of manfacturer.
7.2 Maintenance & Upkeep Of Outdoor Unit
The edge of some sheet metal assemblies and the fin of the
condenser are very sharp. Incorrect operation may cause harm.
Be cautious when cleaning them up.
Check the air inlet and outlet of the outdoor unit periodically to
see whether they are blocked by stain or lampblack.
Contact the distributor or the aftersales service center of
manfacturer.
7.3 Operation Required Before Leaving The Air
Conditioner Idle For A Long Period:
Let the air conditioner run in the air supply mode for about half a
day, and let its interior be fully dry.
Switch off the power by the button in wire controller, and then
cut off the power supply.
When the main power switch is turned on, a certain extent of
electric power is consumed even if the air conditioner does not
run. Turning off the main power switch can save energy.
After the air conditioner has been in service for several seasons,
foreign substance accumulates inside the unit to an extent
dependent on the working conditions. Therefore, shut down the
air conditioner through the ON/OFF button of the remote control-
ler, and then cut off the power supply.
7.4 Startup After A Long Period Out Of Service
Check the following issues:
Check whether the air inlet or outlet of the indoor unit and
outdoor unit is not blocked. Remove foreign substance if any.
Check whether the ground wire is connected properly.
Check
whether
the
normally.(Cooling operation season)
Check whether the insulation work of refrigerant circuit and
ventilating duct is on sound status.
Check whether the installing seat is corroded or rusted.
Startup
Connect the indoor unit 12 hours after connect the outdoor unit
to power supply.
Switch on the power control of remote controller or wired
controller, and than startup the air conditioning.
7.5 Maintenance & Upkeep Of indoor Unit