intensity IC4H-06KF-3 Owner's Manual

intensity IC4H-06KF-3 Owner's Manual

Four-way cassette chilled water
Hide thumbs Also See for IC4H-06KF-3:

Advertisement

Quick Links

IC4H-06KF-3, IC4H-08KF-3, IC4H-12KF-3, IC4H-16KF-3
Four-Way Cassette

Chilled Water

OWNER'S MANUAL
www.intensity.com.mx
MAN-O-IC4H-1112

Advertisement

Table of Contents
loading

Summary of Contents for intensity IC4H-06KF-3

  • Page 1: Chilled Water

    IC4H-06KF-3, IC4H-08KF-3, IC4H-12KF-3, IC4H-16KF-3 Four-Way Cassette Chilled Water OWNER’S MANUAL www.intensity.com.mx MAN-O-IC4H-1112...
  • Page 2: Important Safety Information

    1. IMPORTANT SAFETY INFORMATION To prevent water leak, contact your dealer. When the system is installed and runs in a small room, it is To prevent injury to the user or other people and property required to keep the concentration of the water, if by any damage, the following instructions must be followed.
  • Page 3: Operation Range

    3. OPERATION RANGE Do not place appliances which produce open fire in places exposed to the air flow from the unit or under the indoor unit. Use the system in the following temperature for safe and It may cause incomplete combuston or deformation of the unit effective operation.
  • Page 4: Adjusting Air Flow Direction

    Keep the indoor unit and remote controller at least 1 m away Maintenance after a long stop period from televisions, radios, stereos, and other similar equipment. (eg. at the beginning of the season) Failing to do so may cause static or distorted pictures. Check and remove everything that might be blocking inlet A dirty air filter will reduce cooling or heating efficiency, please and outlet vents of indoor units .
  • Page 5: Following Symptoms Are Not Air Conditioner Troubles

    7. FOLLOWING SYMPTOMS ARE NOT AIR CONDITIONER TROUBLES Re-install the air filter. Install and close the air-in grill in the reverse order of step 1 Symptom 1: The system does not operate and 2 and connect the control box cables to the corresponding terminators of the main body .
  • Page 6: Troubleshooting

    8. TROUBLESHOOTING Symptom 5: Dust comes out of the unit 8.1. Troubles and causes of air conditioner When the unit is used for the first time in a long time. If one of the following malfunctions occur, stop operation, shut This is because dust has gotten into the unit.
  • Page 7 Troubles and causes of remote controller Before asking for serving or repairing , check the following points. (see in table 2) table 2 Symptoms Causes Solution Check whether the MODE When the automatic mode is indicated on the display is selected, the air conditioner will "AUTO"...

This manual is also suitable for:

Ic4h-12kf-3Ic4h-08kf-3Ic4h-16kf-3

Table of Contents