Volumetric Configuration - Omega LVU500 Series User Manual

Reflective ultrasonic transmitter
Table of Contents

Advertisement

LVCN414-SW Appendix

VOLUMETRIC CONFIGURATION

The sensor may be configured in volumetric units
(Gallons or Liters) or Distance (Height of Liquid)
units (inches, cm, feet or meters). LVCN414-SW
will default to Distance (Height of Liquid) with units
of Inches.
To change units or change from
Distance to Volume, press the Volumetric Mode
button as located near the center of the window.
Distance (Height of Liquid): When this is selected,
the sensor will always output a linear output
proportional to the height of liquid (regardless of the
tank shape). In the two drawings below, the Sensor
High is set to 64" and Fill-Height is set to 60". If the
tank is empty, the sensor will output 4mA. If the level
is at 30", then the sensor will output 12mA. Either
tank can be configured with a display from 0" to 60"
and the sensor will always output the height of liquid.
Volume: When volume is selected, the 4-20 mA output from the sensor will be proportional to the volume of
the tank, not the height of the tank. This means that the current output will track the volume of the tank (in
gallons or liters). Depending on the shape of the tank, the values may be a linear or non-linear scale. In the
same examples below, the sensors are also configured with SH = 64" and FH = 60". The current output in a
linear tank will act as expected with volume increase matching equal changes to level. However, the current
output in the Non-Linear tank will reflect the actual changes in volume. So even though the liquid height
changes incrementally the same amount, the volume change will adjust throughout the entire span of the tank.
The advantage of this is that sensor does all the math so you can read tank volume using a simple two-point
display/controller such as the DataLoop
Linear Tank Example
Note: In the above illustration, 10" of liquid will always
be equal to 100 gallons of liquid (1" = 10 gallons).
(continued)
LI25 series or DataView
36
LI55 series.
Non-Linear Tank Example
Note: In the above illustration, 1" of liquid does not equal 10
gallons. The 10" at the bottom represents a rise of 62.8
gallons. As a change between 10" and 20" represents an
increase of 109.6 gallons (i.e. 172.4 gallons – 62.8 gallons).
Section Six

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lvu503Lvu501 seriesLvu503-g-bLvu503-gLvu501-bLvu501 ... Show all

Table of Contents