Trouble Shooting - Parkside PTK 2000 E3 Translation Of The Original Instructions

Table of Contents

Advertisement

Available languages

Available languages

Trouble shooting

Problem
1. Blade dissolves after swit-
ching off the engine
2. Engine will not start
3. Motor wrong direction of
rotation
4. Motor will not work, the
fuse is activ
5. Fire marks on the cutting
surface
Possible cause
To slightly tightened fastening nut
a) Failure mains fuse
b) Defective extension cable
c)
Connections on motor or switch not in order
d) Motor or switch faulty
Capacitor faulty
a) Cross section of the extension cable does not
sufficiently
b) Overload by a blunt saw blade
a) blunt saw blade
b) wrong saw blade
GB
Fault correction
Tighten the right hand thread nut
a) Check mains fuse
b) Replace extension cord
c)
Repair by electrical specialist
d) Repair by electrical specialist
Repair by electrical specialist
a) see „Electrical connection"
b) Change saw blade
a) Sharpen or change saw blade
b) Change saw blade
IE
NI
19