■ Fidaptor

Fidaptor with safety cover
The Fidaptor is included with the torque meter.
Connects clutch-type power screwdrivers to the
torque meter socket, for measurement of torque
Limit Line on the Fidaptor TFG series
● How to Use The Fidaptor TFG series
● Note (to keep accuracy of torque
measurement)
• Loosen the spring up to the desired area for
storing the Fidaptor properly.
• Scratch or wipe with chemicals such as benzin
or alcohol could cause the serigraphed "Limited
line" peel-off.
• We recommend to follow the guide written
in the " maintenance and inspection of of the
Fidaptor " in the operation manual and replace
the Fidaptor driver shaft with a new one after
2,500 strokes.
at the point where the clutch disengages. Features
a safety cover and a mechanism that has almost
the same effect as that obtained in actual tapping
screw fastening work.
Loosen the spring until the top of
the bearing housing reaches to the
desired area.
The desired area to
loosen the spring up to
● Threaded shaft
(comes with Model HP-100)
Use as adapter for bits that are not the 5 mm HIOS
standard diameter. (Refer to diagram on page 10
when changing shock absorber spring.)
- 6 -
Parts name:
Bearing housing