Memory - HIOS HP-10 Operation Manual

Digital torque meters
Hide thumbs Also See for HP-10:
Table of Contents

Advertisement

Memory

Objective
Measurement data can be stored in the memory for
management of everyday operations.
Storing and reading out measurement data
1. The memory can store 100 measurements. The
measurements are numbered automatically, from
0001 to 0100. If data from previous measurements
remains in the memory, the new measurements
begin from the next available number. (Fig. 1)
2. Fig. 2 shows how to display data stored in the
memory.
3. When the 100th result has been stored in the
memory, delete some of the data (Fig. 3) or all of
the data (Fig. 4) to make room for the next series
of measurements.
Memory full display
The fl ickering display "FUL" ap-
pears when the memory is full. To
clear this display, press 【 RESET 】 .
Switch functions in memory mode
Switches used
 
① 
② 
SET
RESET
【 SET 】   switch
① 
When the memory function is on, pressing this
switch displays the last measurement in the
memory.
② 【▲】   switch
When the memory function is on, pressing this
switch displays the first measurement in the
memory.
③ 【 RESET 】   switch
When the memory function is on, pressing this
switch returns the instrument to a state of readi-
ness to begin recording data again. Press to end
recording, to display or to delete data.
④ 【 M_SET 】 switch
Press for 2 seconds to enter or exit measuring
mode. The LED lights when measuring mode is
on.
⑤ 【 M_CR 】 switch
Pressing this switch deletes memory contents.
Note that data can be output (see "Data Output"
on page 8) whether or not the LED is on.
③ 
④ 
M_SET
M_CR
Fig. 1 Recording readout
Example of memory readout
Memory mode on (LED on)
Ready for
measurement
Fit the power screwdriver into the socket,
Measurements of driver
using the Fidaptor or other adapter
torque
When the memory function is on, pressing this
switch returns the instrument to a state of
③ 【RESET】 switch
readiness to begin recording data again. Press
to end recording, to display or to delete data.
Fig. 2 Displaying recorded data
Example of data display
(Memory function on, LED on, measurement data in memory)
Ready for
measurement
【SET】 advances the display to the next measure-
①② 【SET】 and 【▲】
ment result.【▲】 goes back to the previous meas-
switches
urement result.
Press once to advance the display to the next data result.
① 【SET】 switch
The data number (e.g. 0002) is displayed below. The
measurement data and data number flicker alternately.
Press once to advance the display to the previous
② 【▲】 switch
data result.
Data readout mode terminated when this switch is
pressed, when there is no action for 30 seconds or
③ 【RESET】 switch
a new torque signal is received.
Fig. 3 Partial deletion of measurement data
Example of partial deletion of torque value data
(Memory function on, LED on, measurement data in memory)
Ready for measurement
Memory readout mode
on
⑤【M_CR】 switch
Exit partial deletion mode 【RESET】 pressed or no action for 30 seconds
Data deleted
⑤【M_CR】 switch
* Partial deletion of measurement results
Data shifts to previous position
DATA1
DATA2
DATA3
0001
0002
Fig. 4 Full deletion of measurement data
Example of full deletion of measurement data
(Memory function on, LED on, measurement data in memory)
Ready for measurement
Press for
⑤【M_CR】 switch
2 seconds
Exit full deletion mode 【RESET】 pressed or no action for 30 seconds
Data deleted
⑤【M_CR】 switch
- 9 -
Display measurement result for deletion
Partial data deletion mode display
Press
Display flickers
once
Each time a measurement result is delet-
ed, each of the measurement results shift
one place backwards to occupy the va-
cated places in the memory.*
DATA4
0003
0004
DATA1
DATA3
DATA4
0001
0002
0003
Full data deletion mode display
Display flickers
Press once; data deletion takes 5 seconds
0004

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hp-1Hp-100

Table of Contents