Electrolux EWX11831 Service Manual page 72

Uimc / emc14 inverter. series 7/8/9.
Hide thumbs Also See for EWX11831:
Table of Contents

Advertisement

Alarm
Alarm Description
Code
EA1
DSP system failure
EA6
DSP door open failure
EB1
Power supply frequency out
(EH1)
of limits
EB2
Power supply voltage too
(EH2)
high
EB3
Power supply voltage too low
(EH3)
EBD
Heater WD relay
(EHD)
sensing alarm
EBE
FCV Relay failure
(EHE)
EC1
Electro valves blocked
Weight sensor
EC2
communication error
EC3
Weight sensor fault
EC8
TY5 triac failure
EC9
TY5 triac sensing failure
Technical Support - DMM
Fault Condition
Wiring or main board defective
Not drum position sensing
DSP sensor failure
during motor activation
Main motor belt broken
Not sufficient number of
Wiring or main board defective
tachometer impulses
Main motor belt broken
during motor activation
Lid open
Power supply period
lower/higher than
Wrong or disturbed Power Supply line. Main board defective
configured values
MAIN_V sensing input
voltage value greater than
Wrong or disturbed Power Supply line. Main board defective
configured value
MAIN_V sensing input
voltage value lower than
Wrong or disturbed Power Supply line. Main board defective
configured value
Wrong input signal to
Main board defective
microprocessor
Incongruence between
FCV Relay defective
safeties relay sensing and
FCV sensing circuit defective
FCV relay status
Wiring or main board defective
Flow meter running with
Electro valves defective/blocked
electro valves switched
Main board defective
OFF
Communication problem
Wiring defective
between
Weight Sensor defective
Weight sensor and MB
MB defective
Weight sensor defective
Signal coming from sensor
Main board defective
out of limits
Wiring
Incongruence between
TY5 triac load device defective (motor fan/hot valve/water
TY5 triac sensing and triac
softener board)
status
Wiring or main board defective
Wrong input signal to
Main board defective
microprocessor
Possible Fault
72/106
Machine Action/Status
Reset Key
Skip of the drum positioning
START
phase
RESET
START
Cycle paused
RESET
Wait for nominal power supply
OFF/ON
conditions
Wait for nominal power supply
OFF/ON
conditions
Wait for nominal power supply
OFF/ON
conditions
Cycle blocked with door
RESET
locked
Safety Drain cycle activation,
stop of the cycle with door
RESET
opened
Cycle blocked
Water drain up to anti-boil
level or max. 5 minutes with
RESET
door locked. When O.L.
blocked drain pump ON/OFF
for 5/5 minutes continuously
START
No actions
RESET
START
No actions
RESET
Safety Drain cycle activation.
RESET
Cycle blocked
Safety Drain cycle activation.
RESET
Cycle blocked
599 77 23-65 Rev. 03

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: