8 ALARMS

8.1 Displaying user alarms

When a problem occurs in the appliance and a "WARNING" or "ALARM" is triggered, this is shown in the three
digit display (where the time left to the end of the cycle is shown), this information ceases to be displayed when
the problem is repaired/solved. The buzzer then emits a sound for 5 minutes. This does not occur for alarm EH0.
Series 7
The alarms displayed to the user are listed below:
 E10 – Water fill difficulty (tap closed)
 E20 – Drain difficulty (filter dirty)
 E40 – Door open
The alarms listed below:
 EF0 – Water leakage (Aqua Control System)
The intervention of a service engineer is required.
For the alarm on the other hand:
 EH0 – Voltage or frequency outside the normal values
It is necessary to wait for power supply voltage and/or frequency to restore normal conditions.
The alarms are enabled during the execution of the washing programme. With the exception of alarms
associated with the configuration and the power supply voltage/frequency, which are also displayed
during the programme selection phase.
The door can normally be opened (except where specified) when an alarm condition has occurred, on the
condition that:
The water in the tub is below a certain level.
The water temperature is lower than 55°C.
The motor has stopped.
Certain alarm conditions require a drain phase to be performed before the door can be opened for safety reasons:
Cooling water fill if the temperature is higher than 65°C.
Drain until the analogue pressure switch is on empty, during a max. 3-minute interval.

8.2 Reading the alarms

The last three alarms stored in the FLASH memory of the PCB can be displayed:
Enter the diagnostic mode (para. 7.1)
Irrespective of the type of PCB and configuration, turn the programme selector
knob clockwise to the eleventh position.
the last alarm is displayed.
To display previous alarms, press/touch the button/sensor to the left of the
START/PAUSE button in sequence (as shown in the figure).
To return to the last alarm, press/touch the START/PAUSE button/sensor.
SERIES 7
Technical Support - DMM
Series 8
SERIES 8
36/106
Series 9
SERIES 9
599 77 23-65 Rev. 03