Appendix A : Isolated Dio Guide - Cybernet IPC-R1ix User Manual

Fanless robust computing system with 4 pci/pcie slots, 3rd gen. intel core i7/ i5/ i3 mobile processor
Table of Contents

Advertisement

A

APPENDIX A : ISOLATED DIO GUIDE

Description:
Initialize hardware and resources, and get number of functional borads.
Syntax:
I16 _mnet104_open ()
Argument:
Name
N / C
Return:
Return Value
ERR_NoError
Other
Description:
Get the local DI value.
Syntax:
I16 _mnet104_read_port( U16 Offset, U8 *Val )
Argument:
Name
Offset
Val [output]
Return:
Return Value
ERR_NoError
Other
Type
Please reference to the Appendix error table.
Type
U16
Pointer the access DI port address
U8 *
Return the value of local input interface.
Please reference to the Appendix error table.
Description
Description
Description
Description
Appendix A
79

Advertisement

Table of Contents
loading