Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Cybernet CyberMed S22

  • Page 2 CyberMed / iOne S22 / S24 / S24K User Manual FCC-B Radio Frequency Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 3 Safety Instructions Always read the safety instructions carefully. Keep this equipment away from humidity. Lay this equipment on a reliable flat surface before setting it up. The openings on the enclosure are for air convection hence protect the equipment from overheating. DO NOT COVER THE OPENINGS. Confirm the voltage of the power source and adjust accordingly to 110/220V before connecting the equipment to the power inlet.
  • Page 4 WEEE Statement (Waste Electrical and Electronic Equipment) The WEEE directive places an obligation on EU-based manufacturers, distributors, retailers and importers to take-back electronics products at the end of their useful life. A sister Directive, ROHS (Restriction of Hazardous Substances) compliments the WEEE Directive by banning the presence of specific hazardous substances in the products at the design phase.
  • Page 5: Table Of Contents

    A – Internal Battery behavior of the CyberMed / iOne S series ........30 B - Battery Storage and Maintenance ................ 31 C - Cybernet Limited Warranty ................... 32 D - Cybernet’s Recycling Program ................33 E - Getting Help ......................33...
  • Page 6: Introduction

    Ready to use Alternating current Getting to Know Your All in One PC This manual refers to both the Medical CyberMed S22 / S24 / S24K models and the Enterprise iOne S22 / S24 / S24K models. Model difference: 1) CyberMed units: Features a white colored unit for medical markets with Antimicrobial and Medical grade certifications.
  • Page 7: Cybermed / Ione S22 / S24 / S24K Specifications

    CyberMed / iOne S22 / S24 / S24K Specifications S22: LCD panel 21.5” 1920 x 1080 250nits S24: LCD panel 23.6” 1920 x 1080 250nits Display S24K: LCD panel 23.6” 3840 x 2160 300 nits Support Intel Skylake/Kabylake platform Intel® Core™ i7-6600U/7600U Intel®...
  • Page 8 HID DigitalPersona 4500 Fingerprint Reader 19V / 6.32A with FSP, FSP120-REBN2 for UL/IEC60950-1 19V / 7.89A with FSP, FSP150-ABBN3 for UL/IEC60950-1 and UL/IEC62368-1 Power Input 19V / 6.32A with FSP, FSP-120-ABBN3 for UL/IEC60950-1 and UL/IEC62368-1 19V / 6.31A with EDAC, EM11011M for UL60601-1 19V / 7.89A with EDAC, EM11701F for UL60601-1 10F Multi-touch capacitive touch Touch Screen...
  • Page 9: Power Information

    ANSI/AAMI ES60601-1 (2005) + AMD1 (2012) and CAN/CSA- C22.2 No. 60601-1:14 UL/IEC60950 / 62368 REACH / RoHS 3.0 / WEEE Power Information: FSP120-REBN2, 120W, Made by FSP TECHNOLOGY INC. for UL60950-1 FSP150-ABBN3, 150W, Made by FSP TECHNOLOGY INC. for UL60950-1 / 62368 FSP120-ABBN3, 120W, Made by FSP TECHNOLOGY INC.
  • Page 10: Drivers

    Unpacking After opening the carton, please check carefully to see if there are any damages or missing parts. Read the Manual Please read the important tips and safety notices in the manual before using your computer. Be sure to keep this manual for future reference. Drivers Please visit https://www.cybernetman.com/en/support/downloads...
  • Page 11: Electrical And Power Source Related

    uneven surfaces may cause the cart to overturn or fall. 2. If the S unit is dropped, immediately turn the power off, disconnect the cords, and contact a service technician for repairs. Continual use of the system after a damaging drop may result in a fire or electric shock. Also, do not repair the unit on your own.
  • Page 12: Environmental Factors

    : To avoid risk of electric shock, this equipment must only be connected to a WARNING supply mains with protective earth. Disconnect Device ▪ To fully disengage the power to the unit, please ensure the system has been properly shutdown before disconnecting the power cord from the AC inlet. Environmental Factors ▪...
  • Page 13: Servicing, Repairing, Maintenance & Safety Checks

    such as a built-in shelf. Keep a minimum distance of 10 cm between the unit and any walls. Servicing, Repairing, Maintenance & Safety Checks 1. If the unit is not functioning properly, observe the performance level closely to determine what type of servicing is needed. 2.
  • Page 14 ISO 7000-0434: Caution, consult ACCOMPANYING DOCUMENTS. ISO 7000-1641: Follow operating instructions or consult instructions for use. IEC 60417 -5009: ready to use. IEC 60417-5031: Direct current. EU-wide legislation, as implemented in each Member State, requires that waste electrical and electronic products carrying the mark (left) must be disposed of separately from normal house hold waste and follow the “national”...
  • Page 15: Cybermed & Ione S Series Overview

    CyberMed & iOne S series Overview CyberMed & iOne S22 DOC ID: 16000200...
  • Page 16 CyberMed & iOne S24 / S24K DOC ID: 16000200...
  • Page 17: On Screen Display Buttons

    On Screen Display Buttons There are four buttons on the lower bezel as shown above. From right to left: OSD Key Response Time Function Power button Delay 1.5 sec Main power ON/OFF button. Press once to enter the On-screen display (OSD) menu.
  • Page 18: Side I/O View

    Side I/O View Item Description Complies with ISO7816 –1,2,3 T=1 and T=0 protocol. Smart Card Reader Complies with FIPS 140-2. (Optional) Memory card: Synchronous 2-line,3-line and I2C Interface, EMV L1 (Version 2000) 2 x USB 2.0 The USB interface supports Plug and USB2.0 Ports Play.
  • Page 19: Back View

    Back view Item Description Bracket Hole Reserved for optional external modules: Finger Print module / MSR / NFC Win7: The button will input “CTRL + ALT + DEL”. SAS KEY Win8.1/10: The button will function as a “Start button”. Hold for 3 seconds to input “CTRL + ALT + DEL”. VESA mount hole Supports 75 x 75 and 100 x 100 VESA mount using M4 screws*4 (4.0mm x 12.0mm).
  • Page 20: Bottom View

    Bottom View Item Description DC-IN 19V input with 120/150Watt adapter. RS232/RS422/RS485 is selectable at pin 9. COM1 5V/12V is selectable in the BIOS menu (100mA max). Intel I219LM 10/100/Gigabit LAN, supports Wake on LAN, PXE LAN1 boot and vPro technology. Realtek RTL8111 10/100/Gigabit LAN, supports Wake on LAN LAN2 and PXE boot.
  • Page 21: Power Management

    Power Management Power management has the potential to save significant amounts of electricity as well as deliver environmental benefits. To be energy efficient, turn off your display or set the AIO PC to sleep mode after a period of user inactivity. Power Management in Windows OS Right click the start button, and select [Power Options].
  • Page 22 Select a power plan that suits your personal needs. You may also fine-tune the settings by clicking [Change plan settings]. The Shut Down Menu presents the options of Sleep (S3) & Shut Down (S5) for rapid and easy management of your system power. Power Management through ENERGY STAR qualified Monitors (Not supplied with the AIO PC) The power management feature allows the AIO PC to initiate a low-power or “Sleep”...
  • Page 23 Waking the System Up The AIO PC shall be able to wake up from power saving mode in response to a command from any of the following: ▪ the power button, ▪ the network (Wake on LAN), ▪ the mouse ▪...
  • Page 24 Power Save Settings for Windows Under Control Panel → System and Security → Power Options Change from “Balanced” mode to “Power saver” mode Once power saver is enabled, the following icon will appear in Windows 10: The power saver feature helps conserve power when a system is running on its battery. When battery saver mode is on, some Windows features may be disabled or behave differently.
  • Page 25: Bios Setup

    BIOS Setup The AMI BIOS provides a Setup utility program for specifying system configurations and settings. The BIOS ROM of the system stores the Setup utility. When you turn on the computer, the AMI BIOS is immediately activated. Pressing the <DEL> key allows you to enter the Setup utility.
  • Page 26: Cleaning The Surface Of The All In One Pc

    Below are the approved disinfectants for your AIO PC. The disinfectants have been validated on both housing and the touch glass. To prevent potential damage to the computers, please use the disinfectants listed below. Should you have any questions, please contact Cybernet. Cleaner Brand Viraguard®...
  • Page 27: Servicing The Hdd

    Servicing the HDD 1. Ensure that the AIO PC is powered off. Unplug the power adapter before servicing the HDD. 2. To access the HDD bay, first remove the sticker in the highlighted area below. Then unscrew the HDD bay cover. Next, lift the HDD bay cover up to remove. 3.
  • Page 28: Troubleshooting

    - The memory is installed correctly. If these items are properly set, and the screen remains blank, try the clear CMOS procedure. https://www.cybernetman.com/kb/article/how-to-perform- the-clear-cmos-procedure-on-your-cybernet-pc If the clear CMOS proecdure does not work, have the AIO PC serviced. When I turn on the AIO...
  • Page 29 The screen is blank. Check the following: - Check the screen brightness setting. - If the AIO PC is in sleep mode, press the power button to resume the AIO PC. - If the problem persists, refer to the solution in the following problem "the screen is unreadable or distorted."...
  • Page 30: Appendices

    Appendices DOC ID: 16000200...
  • Page 31: A - Internal Battery Behavior Of The Cybermed / Ione S Series

    A – Internal Battery behavior of the CyberMed / iOne S series The internal battery can be charged by the system when the power adapter is plugged in. While the power adapter is plugged in, the system will take 7 hours to charge from 6% to 99%.
  • Page 32: B - Battery Storage And Maintenance

    • The battery typically has a lifespan of 300 cycles under normal usage and operating conditions. After 300 cycles, the battery capacity may lower to 80% of its original capacity. Therefore, Cybernet recommends to replace these batteries for new batteries for a better run time experience. Using the AIO PC in a higher or lower ambient temperature affects the total number of cycles in the battery's service life.
  • Page 33: C - Cybernet Limited Warranty

    C - Cybernet Limited Warranty What the warranty covers Cybernet warrants its products to be free from defects in material and workmanship during the warranty period. If a product proves to be defective in material or workmanship during the warranty period, Cybernet will, at its sole option, repair or replace the product with a similar product.
  • Page 34: D - Cybernet's Recycling Program

    D - Cybernet’s Recycling Program E - Getting Help Corporate Headquarters UK & European Inquiries Cybernet Manufacturing Cybernet Europe 5 Holland #6, Groveland Business Centre Irvine, California 92618 Boundary Way Free: (888) 834-4577 Hemel Hempstead, HP2 7TE Phone: (949) 600-8000...

This manual is also suitable for:

Cybermed s24 cybermed s24kIone s22Ione s24Ione s24k

Table of Contents