Maintenance Cycle; Every 10 Hours - Spraying System; Every 10 Hours - Boom Filters (Optional) - Hardi RANGER 2500 TR2 Instruction Manual

Table of Contents

Advertisement

Maintenance cycle

Every 10 hours - Spraying system

Fill the tank with clean water, operate all the functions using a higher pressure than normal and check for leaks. Visually check
the spectrum of the jets at the exit from the nozzles, using clean water.
Every 10 hours - Nozzle filters
Check and clean.
Every 10 hours - Suction filter
Suction filter maintenance:
1. Remove pin (A).
2. Remove suction pipe connector (B) from its seating.
3. Filter (C) and its support are now accessible.
To re-assemble:
4. Replace the support on the end of the filter.
5. Put the filter in position with the support facing upwards.
6. Check the condition of gasket (D) on the pipe connector and
grease it.
7. Re-fit suction pipe (B) and pin (A).
±
WARNING! Before you open the filter, put on gloves and
protective clothing.

Every 10 hours - Boom filters (optional)

If the boom is fitted with filters, unscrew the filter bowl, check the
strainer and clean it. Grease the gasket before re-assembling.
There are several mesh sizes available. Refer to the Technical
Specifications section - Filters and nozzles.
±
WARNING! Avoid splashing mixture when unscrewing the filter
bowl.
±
WARNING! Before you open the filter, put on gloves and
protective clothing.