SOURce<n>:DATA:OUTPut <start_addr>,<end_addr>
Parameter
<start_addr>
Hexadecimal number
<end_addr>
Hexadecimal number

5.2.8 DISPlay Subsystem

The DISPlay subsystem controls the instrument's display.
DISPlay:BRIGhtness <brightness>|MINimum|MAXimum
DISPlay:BRIGhtness? [MINimum|MAXimum]
Set the display bringhtness.
Parameter
1%至 100%, default 50%
DISPlay:BRIGhtness 80
DISPlay:SAVer ON|OFF
DISPlay:SAVer ?
Enable or disable display saver.
Parameter
ON|OFF, default ON
Enable display saver: DISPlay:SAVer:STATe ON

5.2.9 FM Subsystem

SOURce<n>:MOD:FM:DEViation <deviation>|MINimum|MAXimum
SOURce<n>:MOD:FM:DEViation? [MINimum|MAXimum]
Sets the peak frequency deviation in Hz.
Parameter
Default 500Hz
Set peak frequency deviation to 1 kHz: SOURce1:MOD:FM:DEViation 1000
 The deviation cannot exceed the carrier frequency. If you attempt to set a deviation that
exceeds the carrier frequency (with FM enabled), the instrument will adjust the deviation to
the maximum value allowed for that carrier frequency.
 The carrier frequency plus the deviation cannot exceed the selected function's maximum
frequency plus 100 kHz. If you attempt to set the deviation to an invalid value, the instrument
adjusts it to the maximum value allowed with the present carrier frequency.
 If the deviation causes the carrier waveform to exceed a frequency boundary for the current
HDG2000 Series Arbitrary Waveform Generator
, from 0x00to 64M, 4Byte
, from 0x00to 64M, 4Byte
Typical Return
80%
Typical Return
ON, or OFF
Typical Return
+1.000000000000000E+03