4. Hold the pipe in the fitting for 30 seconds to pre-
vent tapered socket from pushing the pipe out of
the fitting.
5. Wipe all excess cement from the joint with a rag.
Allow 15 minutes before handling. Cure time varies
according to fit, temperature and humidity.
NOTE: Follow venting instructions carefully when us-
ing PVC cement.
IMPORTANT:
All joints must be water tight. Flue condensate is
somewhat acidic, and leaks can cause equipment dam-
age.
Connection of the pipe and collar of the combustion air
inlet should just be a friction fit. It is recommended that
the inlet air joint be sealed with RTV type sealant to al-
low the joint to be separated for possible future service.
The inlet and vent pipes must be properly supported
throughout the entire length. See Figure 12.
PVC VENT FITTING MATERIAL These fittings are available from your Gas Furnace Distributors.
ASTM STANDARD
F891
D2665
D1785
D2241
ASTM STANDARD
D2846
F441
F442
ASTM STANDARD
D2661
F628
*
- Allowable temperatures based on classifications covered in ASTM D4396 [Deflection Temps Under Load (264 PSI)]
** - Allowable temperatures based on classifications covered in ASTM D1784 [Deflection Temps Under Load (264 PSI)]
*** - Allowable temperatures based on classifications covered in ASTM D3965 [Deflection Temps Under Load (264 PSI)]
14
TABLE 4
PLASTIC PIPE DESIGNATIONS
PVC
PIPE TYPE
CELLULAR CORE
DWV PIPE
SCH 40, 80, 120
SDR SERIES
CPVC
PIPE TYPE
CPVC 41
SCH 40, 80
SDR SERIES
ABS
PIPE TYPE
SCH 40 DWV
SCH 40 DWV CELLULAR CORE
NOTE: Vent termination kit BAYAIR30AVENTA or
BAYVENT200B may be used in addition to the horizon-
tal and vertical termination options shown in the fol-
lowing figures.
A variety of potential sources of carbon monoxide can be
found in a building or dwelling such as gas-fired clothes
dryers, gas cooking stoves, water heaters, furnaces and
fireplaces. The U.S. Consumer Product Safety Commis-
sion recommends that users of gas-burning appliances
install carbon monoxide detectors as well as fire and
smoke detectors, listed by a nationally recognized
agency (e.g. Underwriters Laboratories or International
Approval Services), to help alert dwelling occupants of
the presence of fire, smoke or unsafe levels of carbon
monoxide.
NOTE: The manufacturer of your furnace does not test
any detectors and makes no representations regarding
any brand or type of detector.
ALLOWABLE TEMPERATURE
*158
**158
**158
**158
ALLOWABLE TEMPERATURE
**212
**212
**212
ALLOWABLE TEMPERATURE
***180
***180
MARKING
ASTM F891
ASTM D2665
ASTM D1785
ASTM D2241
MARKING
ASTM D2846
ASTM F441
ASTM F442
MARKING
ASTM D2661
ASTM F628