After installation has been completed, it is recommended that the Furnace be checked against the following
checklist.
1. Make
sure
power
disconnect switch ............................................... [ ]
2. Check all field wiring for tight connections.
See that grounding of unit is in accord with code.
........................................................................... [ ]
3. Make sure unit suspension (if used) is secure
and that there are no tools or loose debris in,
around or on top of the unit .............................. [ ]
4. Check all duct outlets; they must be open
and unrestricted ................................................ [ ]
5. Check drain lines and be sure all joints are tight ..
........................................................................... [ ]
6. Make sure secondary drain pan is installed ..... [ ]
7. Check power supply for correct requirements
per unit nameplate ............................................ [ ]
8. Energize
the
system
its operation; make any necessary adjustment [ ]
9. Adjust ozone setting, if needed ......................... [ ]
10. Instruct owner on proper operating procedure and
leave Use and Care Manual with owner .......... [ ]
18-CD25D1-2
CHECKOUT PROCEDURES
is
"OFF"
at
power
and
carefully
observe
Installer's Guide
11. Check the Whole House Air Cleaner power output
by the Green LED illumination. If the LED is on,
this indicates High Voltage output to the air
cleaner. .............................................................. [ ]
a) Turn the Comfort Control to fan only.
b) Remove blower door panel.
WARNING
!
RISK OF ELECTRICAL SHOCK:
ELECTRICAL POWER IS PRESENT FOR THE
NEXT 2 STEPS. THESE STEPS SHOULD BE
PERFORMED ONLY BY QUALIFIED PERSON-
NEL.
FAILURE TO FOLLOW THIS WARNING COULD
RESULT IN PERSONAL INJURY, ELECTRICAL
SHOCK, OR DEATH.
c)
Depress blower door switch.
d) Verify with Fan running that Green LED is il-
luminated.
e) Release Blower Door Switch and put Blower
Door back on.
f)
Turn Comfort Control to desired position.