Integrated Air Controls

To reduce the risk of serious injury whenever you are
instructed to relieve the pressure, follow the Pressure
Relief Procedure.

Pressure Relief Procedure

1. Close the air motor slider valve (E) and the main air
slider valve (F).
2. Set the ram director valve to DOWN. The ram will
slowly drop.
3. Jog the director valve up and down to bleed air from
ram cylinders.

Disassembly

1. For Supply Systems with Shrouds: Remove
shrouds. Loosen six captive screws (A) and disas-
semble shrouds (B) from supply system.
B
F
. 1
IG
2. Disconnect all hoses and tubing from existing air
control.
3. Remove four screws (C) from the mounting bracket
(D) and remove the integrated air controls from the
supply system.
312374H
B
255650 (shown)
A
r_289105_312375_a
255650 (shown)
F
. 2
IG
C
D
F
. 3
IG
If you are not replacing the manifold (1), you may
prefer to remove the bracket from the ram and
leave it attached to the integrated air controls
because the screws are easier to reach. See F
Integrated Air Controls
C
D
r_289105_312375_2a
255650 (shown)
E
1
F
r_289105_312375_3a
E
1
F
. 4.
IG
3