Cmd Command
11
Primary Ring
Transfer Count
12
Secondary Ring
Transfer Count
13
Third Ring
Transfer Count
14
Auto Answer
15
Talk Time
16
Operator Wait
Time
17
Operator Prompt
18
Button 2
19
Remote Call
Number
20
Remote Call
Dialing
Frequency
23
SoundNet Code
24
Start PLM Test
30
Volume Setting
31
Microphone
Setting
32
Push & Hold
33
Service Prompt /
Notification
Range
3 – 10 rings
3 – 10 rings
3 – 10 rings
0 = OFF
1 = ON with cab ring tone
2 = ON with no Cab ring tone
3 – 10 minutes
20 – 200 seconds
0 = OFF
1 = ON
Special order only
0 - 23 digits; values 1,2,3,4,5,6,7,8,9,0,#(pause)
Blank = no remote call
0 = OFF
1 = Once (10sec delay after exiting PROG)
2 = Daily, with descriptive prompt
Blank or 11 digits; values 1,2,3,4,5,6,7,8,9,0
0 – 100 seconds (resets to 0 after test)
0 = Soft
9 = Loud
0 = Least sensitive
9 = Most sensitive
0 = OFF – instant single press
1 = ON – hold call button for >= 1sec or 3 times
in a 5sec window
0 = OFF
1 = ON - played every 5min if call not answered
EMC-60 User Guide
Default
5
5
5
1
5
45
1
Blank
0
Blank
N/A
5
5
0
1
- 12 -
Need help?
Do you have a question about the EMC-60 and is the answer not in the manual?
Questions and answers