Page 2
Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Veeder-Root shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this publication.
This guide provides assistance in selecting Dispenser Interface Modules (DIMs) that enable a properly fitted TLS Console to interface supported Point-of-Sale (POS) devices and provide enhanced product inventory and/or product vapor recovery monitoring. Veeder-Root offers two console upgrades that interface with POS devices: Business Inventory Reconciliation (BIR) Business Inventory Reconciliation is a console option that automatically collects dispensing data, in-tank inventories and deliveries, and reconciles the totals at the end of each shift, day, and month.
POS App Guide Introduction Reconciliation reports will be generated for the manifolded set as a single product. Individual adjusted delivery reports will be provided followed by an adjusted manifolded delivery report. Both Version 310 software (or later), and a Memory Expansion Module are required to perform BIR for manifolded tanks.
POS App Guide Introduction such as Schlumberger electronic blending dispensers and mechanical dispensers fitted with fixed-ratio blenders are not supported. MANIFOLDED TANK APPLICATIONS • Maximum number of tanks in a set: unlimited • Maximum number of siphon manifold tanks: number of tanks divided by 2. Limit: 8 •...
CFN2, Petrovend, ANDI V-R meter OTHER APPLICATIONS Many POS / dispenser systems are similar to those identified in this guide. Veeder-Root is constantly evaluating and supporting new applications. If your application is not listed in this guide, contact your Veeder-Root Sales Representative.
DIM Descriptions Mechanical Dispenser Interface Module (MDIM) & Low Voltage Dispenser Interface Module (LVDIM) • The mechanical dispenser interface modules enable the TLS console to monitor either high voltage (MDIM), or low voltage (LVDIM) volume pulses and calculate dispensed volume. •...
POS App Guide DIM Descriptions DIM And Installation Kit Ordering Guide Table 2.- Dispenser DIM and Installation Kits Console Compati- bility Dispenser TLS-350R TLS-450 TLS-450PLUS Controller/ DIM P/N DIM P/N DIM P/N DIM Install Kit Dispenser POS Type w/Console w/Console w/Console Notes For Bennett 92D con-...
Page 13
POS App Guide DIM Descriptions Table 2.- Dispenser DIM and Installation Kits Console Compati- bility Dispenser TLS-350R TLS-450 TLS-450PLUS Controller/ DIM P/N DIM P/N DIM P/N DIM Install Kit Dispenser POS Type w/Console w/Console w/Console Notes Model TCRG TCRG PA0180-121 Model TCRG2 TCRG2 PA0180-121...
Page 14
POS App Guide DIM Descriptions Table 2.- Dispenser DIM and Installation Kits Console Compati- bility Dispenser TLS-350R TLS-450 TLS-450PLUS Controller/ DIM P/N DIM P/N DIM P/N DIM Install Kit Dispenser POS Type w/Console w/Console w/Console Notes TCPIP Interface for Gil- barco SmartCrind dis- pensers only.
Page 15
POS App Guide DIM Descriptions Table 2.- Dispenser DIM and Installation Kits Console Compati- bility Dispenser TLS-350R TLS-450 TLS-450PLUS Controller/ DIM P/N DIM P/N DIM P/N DIM Install Kit Dispenser POS Type w/Console w/Console w/Console Notes A Gasboy site control- ler version 2.0 or later is required.
Page 16
POS App Guide DIM Descriptions Table 2.- Dispenser DIM and Installation Kits Console Compati- bility Dispenser TLS-350R TLS-450 TLS-450PLUS Controller/ DIM P/N DIM P/N DIM P/N DIM Install Kit Dispenser POS Type w/Console w/Console w/Console Notes One or more pulser/ totalizer kits are needed PN 787491- 003.
Page 17
POS App Guide DIM Descriptions Table 2.- Dispenser DIM and Installation Kits Console Compati- bility Dispenser TLS-350R TLS-450 TLS-450PLUS Controller/ DIM P/N DIM P/N DIM P/N DIM Install Kit Dispenser POS Type w/Console w/Console w/Console Notes Allied ANDI. Gilbarco ANDI, with T-14 (Australia).
Page 18
POS App Guide DIM Descriptions Table 2.- Dispenser DIM and Installation Kits Console Compati- bility Dispenser TLS-350R TLS-450 TLS-450PLUS Controller/ DIM P/N DIM P/N DIM P/N DIM Install Kit Dispenser POS Type w/Console w/Console w/Console Notes Use 331354-001 for MEMS IV, 67A/B or 98 instead.
Page 19
POS App Guide DIM Descriptions Table 2.- Dispenser DIM and Installation Kits Console Compati- bility Dispenser TLS-350R TLS-450 TLS-450PLUS Controller/ DIM P/N DIM P/N DIM P/N DIM Install Kit Dispenser POS Type w/Console w/Console w/Console Notes A Wayne site controller and Wayne dispens- Wayne Site ers are required.
DIM Installation Examples Various example DIM installation diagrams are shown in Figure 1 below for reference only. For specific DIM installation details, refer to the appropriate Veeder-Root DIM installation manual. Dispenser Controller Network Junction LDIM, IFSF, Distribution Box & TDIM...
Peripheral controller software 330269-00B (or later) • DIM software 349780-001A (or later) VEEDER-ROOT HARDWARE REQUIREMENTS (REF. TABLE 2) The following equipment is required to interface the TLS to the Bennett POS system: • One Bennett Current Loop Dispenser Interface Module for up to 6 fueling positions •...
POS App Guide DIM Installation Examples ALARM WARNING TLS-350R Console POWER White RJ-45 Communications Cable CONSOLE CDIM Black COMM Shield Cable Adapter Box White RJ-45 Communications Cable CONSOLE for Bennett System Black COMM Shield Cable Adapter Box for Bennett System Shielded 2 Wire Flying Lead Cable 6 feet...
TLS-450PLUS System software Version 6.x (or higher) • BIR option required (TLS-450) VEEDER-ROOT HARDWARE REQUIREMENTS (REF. TABLE 2) The following equipment is required to interface the TLS to the Transac POS: • One Gilbarco Current Loop Dispenser Interface Module for up to 3 current loops •...
POS App Guide DIM Installation Examples WIRING DIAGRAM FOR A TRANSAC CURRENT LOOP INTERFACE A PA0133 distribution box is shown in Figure 3 below. Other box models are slightly different. TLS Console Connects to CDIM Shielded 2 Wire Flying Lead Cable 401-8.eps Figure 3.
DIM Installation Examples Gilbarco TS-1000 POS and PAM Systems The Veeder-Root Gilbarco TS-1000 DIM and DIM installation kit supports the Gilbarco TS-1000 and any POS system using the Gilbarco PAM (Pump Access Module) dispenser controller and Gilbarco dispensers. TLS CONSOLE SOFTWARE REQUIREMENTS TLS-350R with BIR Software Requirements •...
• TLS-450 System software Version 2.x (or higher) • TLS-450PLUS System software Version 6.x (or higher) • BIR option required (TLS-450) VEEDER-ROOT HARDWARE REQUIREMENTS (REF. TABLE 2) The following equipment is required to interface the TLS to the G-Site POS: • One Gilbarco Interface Module •...
POS App Guide DIM Installation Examples Diagram A TLS Console Tank Gauge Connects 25 pin D / RJ-45 Adapter to EDIM (Q13180-03/331138-001) Connect RJ-45 plug into 25 pin D / RJ-45 Adapter (331138-001) RJ45 Modular Cable Connect RJ-45 plug directly to Tank Mon port PC G-SITE Diagram B TLS Console...
• TLS-450PLUS System software Version 6.x (or higher) • BIR option required (TLS-450) VEEDER-ROOT HARDWARE REQUIREMENTS (REF. TABLE 2) The following equipment is required to interface the TLS to the AutoGas Storemaster system: • One Gilbarco Interface Module (for up to 3 current loops) •...
• TLS-450 System software Version 2.X (or higher) • TLS-450PLUS System software Version 6.X (or higher) • BIR option required (TLS-450) VEEDER-ROOT HARDWARE REQUIREMENTS (REF. TABLE 2) The following equipment is required to interface the TLS to the SmartCrind network: • One TCP/IP (TDIM) Interface Module •...
Mechanical blenders that blend fuel prior to the metering process are not supported (not a restriction for ISD only applications). OTHER POS CONSOLES Other POS consoles that interface to the Tokheim DHC may also be supported. Contact Veeder-Root for assistance. INSTALLATION NOTES...
Page 37
POS App Guide DIM Installation Examples 401-17.eps ALARM TLS-350R Console WARNING POWER T1: PREMIUM UNLEADED VOLUME 4208 GALS ULLAGE 5792 GALS 90% ULLAGE 4792 GALS TC VOLUME 4194 GALS HEIGHT 41.02 INCHES WATER VOL GALS WATER 0.00 INCHES TEMP 65.0 DEG F T1: REGULAR GASOLINE VOLUME...
Page 38
POS App Guide DIM Installation Examples TLS-350R Console ALARM WARNING POWER T1: PREMIUM UNLEADED VOLUME 4208 GALS ULLAGE 5792 GALS 90% ULLAGE 4792 GALS TC VOLUME 4194 GALS HEIGHT 41.02 INCHES WATER VOL GALS WATER 0.00 INCHES TEMP 65.0 DEG F T1: REGULAR GASOLINE VOLUME 9038...
(PIB). A partial list of these systems include: • GasBoy • Omron • Panasonic • S.A.S.I. • Suntronics • Verifone • EDS C-Serve The third party POS system will be supported by the Veeder-Root DIM if it communicates to the Wayne Site Controller using the Wayne PIB.
POS App Guide DIM Installation Examples INSTALLATION NOTES All Wayne electronic blenders are supported. An example Wayne interconnection diagram for current loop installations is shown in Figure 15. An example Wayne connection diagram for IDPOS dispenser installations is shown in Figure 16. Figure 17 contains an example of CAB connections in a Wayne Nucleus Data Box.
Page 41
POS App Guide DIM Installation Examples Left Current Loop Right Current Loop 401-21.eps Set adjacent toggle switch to right ('Auto' position) Set adjacent toggle switch to right ('Auto' position) To CAB To CAB marked marked 'Left' 'Right' Wayne Data Box PC board ( cover plate removed) Data Data...
• Peripheral controller software 002B (or higher) • DIM software 330435-001 (or higher) VEEDER-ROOT HARDWARE REQUIREMENTS (REF. TABLE 2) The following equipment is required to interface the TLS to the Schlumberger POS system: • One Schlumberger Current Loop Dispenser Interface Module (for up to 32 fueling positions), or One Schlum- berger SAM Dispenser Interface Module (for up to 36 fueling positions) •...
Page 43
POS App Guide DIM Installation Examples TLS-350R Console ALARM WARNING POWER Connects to Cable Adapter Box RJ-45 CDIM RJ-45 Communications Cable (–) Allied Protocol Box To Cable (PCB) MicroMax Adaptor Box (Pump Distribution Box) Wire Nut Connector Required (Note: These two 25 pin “D” connectors are only to be used with Allied Station Schlumberger MicroMax 3000 or Equivalent...
Page 44
POS App Guide DIM Installation Examples 401-25.eps ALARM WARNING POWER TLS-350R Console Connects to RJ-45 CDIM Communications RJ-45 Cable Cable Adapter Port 5 Port 2 Tokheim DHC Schlumberger MicroMax Figure 21. MicroMax POS with Tokheim DCHC Controller Box and RS-232 CAB Interface 401-26.eps ALARM WARNING...
TLS CONSOLE SOFTWARE REQUIREMENTS TLS-350R with BIR Software Requirements • System software Version 17 (or higher) VEEDER-ROOT HARDWARE REQUIREMENTS (REF. TABLE 2) The following equipment is required to interface the TLS to the Gasboy CFN system: • One Gasboy Dispenser Interface Module •...
Page 46
POS App Guide DIM Installation Examples TLS-350R Console 401-27.eps ALARM WARNING POWER To Plug-In Connector on LDIM GND TX- TX+ RX- RX+ Terminal block inside RS-422 junction box Gasboy P/N C05020 Cable shield SITE CONTROLLER II Ground Port 1 Port 3 TX- RX+ RX- GND C05020 Port 2 Cons...
BIR Protocol DIM POS SYSTEM REQUIREMENTS AND LIMITATIONS Any POS system can conform to established Veeder-Root protocol, to allow the TLS to collect the metered sales data necessary to perform BIR and AccuChart tasks. This protocol is separate and distinct from the inventory protocol commonly used by POS and other systems to collect inventory data from Veeder-Root TLS Consoles.
Requires a pulser/totalizer or pulse transmitter and a safe barrier device for each fueling position. Only Veeder-Root mechanical dispensers are supported. TLS-450/TLS-450PLUS MDIM APPLICATIONS Up to 12 single product fueling positions are supported per module, and a maximum of 4 modules (48 fueling positions) per system are supported.
Page 49
POS App Guide DIM Installation Examples MDIM Orange/ Blue Blue White 769780-012 Barrier Pulse P/N: 7859 Transmitter Orange Black Orange Blue White Barrier P/N: 7859 Orange Black Orange/ Blue Not used Note: Barriers may come 769780-012 with a 2 position connector. Pulse Transmitter Orange...
Page 50
POS App Guide DIM Installation Examples 401-29.eps Figure 26. Mechanical Dispenser Applications Using 7874 Series Pulser/Totalizer...
Page 51
POS App Guide DIM Installation Examples Typical Wiring for Meter Stand Applications 769780-008 401-30.eps Pulse Transmitter GALLONS 0 0 0 0 0 Meter Register Metal Conduit Metal Divider Plate "J" Box Explosion Proof Typical Electric Wiring Trough Low Voltage Area Barrier No.
Page 52
POS App Guide DIM Installation Examples 769780-008 Pulse Transmitter GALLONS 0 0 0 0 0 MDIM Meter Register Metal Conduit Metal Divider Plate "J" Box Explosion Proof Typical Electric Wiring Trough Low Voltage Area Barrier No. 7859 Orange #14 AWG (7 x 36 Stranded Wires, Gas &...
POS App Guide DIM Installation Examples LVDIM Applications • TLS-350 - Up to 4 single product fueling positions are supported per module, and a maximum of 8 modules (32 fueling positions) per system are supported. • TLS-450 /TLS-450PLUS- Up to 12 single product fueling positions are supported per module, and a maximum of 4 modules (48 fueling positions) per system are supported.
Page 54
POS App Guide DIM Installation Examples Set SW1 (on module's PC board) to the EXTERNAL position. LVDIM Negative terminals not used w/ SW1 in the EXTERNAL position. PetroVend System 2 PV270 Pump Relay Board Common To Pulsers Pulser To Other PetroVend Hand/Flow PV270...
POS App Guide DIM Installation Examples KRAUS MICON 200 ELECTRONIC DISPENSERS Caution! Kraus Micon Applications Are Not U.L. APPROVED. Each dispenser must provide “volume” pulser output to LVDIM. Installer will have to pull special shielded, UL/CSA type #18 AWG RS-422/485 style, gas, oil, and fire resistant twisted pairs in metal conduit. LVDIM is connected to the DC junction box inside the Micon 200 electronic dispenser head and thence to the pulsers.
Page 56
POS App Guide DIM Installation Examples Set SW1 (on module's PC board) to the INTERNAL position. LVDIM To Other Micon 200 Electronic Dispenser Heads Yellow #18 AWG (Pulser Common Line) Blue #18 AWG Not used (Volume Pulser Output) Micon 200 INPUT RATING Electronic Dispenser Head 30 VDC MAX...
POS App Guide DIM Installation Examples WIRING TO GASBOY 9800 OR TOKHEIM 2600 SERIES ELECTRONIC DISPENSERS Special shielded UL/CSA type #18 AWG RS-422/485 style, gas, oil, and fire resistant twisted pairs must be pulled between pulsers and LVDIM module in metal conduit. GasBoy 9800 or Tokhiem 2600 Series Electronic Dispenser Head 401-33.eps...
Page 58
POS App Guide DIM Installation Examples Set SW1 (on module's PC board) to the INTERNAL position. LVDIM To Other GasBoy 9800 or Tokhiem 2600 Series Electronic Dispenser Heads Pulse 1 (Red) Pulse 2 (Grn) DC Ground (Wht) Not used DC Junction Box GasBoy 9800 or Tokhiem 2600 Series INPUT RATING Electronic Dispenser Head...
Page 59
For technical support, sales or other assistance, please visit: www.veeder.com...