Specific gravity meters / gas specific gravity measurement (28 pages)
Summary of Contents for Emerson Micro Motion 7829 Viscomaster Dynamic
Page 1
Product Data Sheet PS-001199, Rev. C April 2013 ® ™ Micro Motion 7829 Viscomaster Dynamic Viscosity Meter ® Micro Motion viscosity meters are built to tackle the most demanding process and marine applications. Rugged and reliable direct insertion meters with very low maintenance, they provide fully integrated “fit and forget” viscosity measurement.
Product 2 – High Viscosity Response amplitude Product 1 Product 2 Frequency (Hz) Bandwidth = Point B – Point A Resonant Frequency = (Point A + Point B) / 2 Quality Factor = Resonant Frequency / Bandwidth Micro Motion 7829 Viscomaster Dynamic Viscosity Meter...
ADView or ProLink II (v2.9 or later) software tools to configure or diagnose a meter via the RS-485/ Modbus interface. See “ADView Software Tool Features” and “ProLink II Software Tool Features” for more information. Micro Motion 7829 Viscomaster Dynamic Viscosity Meter...
Page 5
Setting up a serial link to communicate with the 7829 transmitter • Configuring the 7829 transmitter • Displaying data real-time or as a graph • Logging data to a file • Verifying correct operation of the system and diagnosing faults Micro Motion 7829 Viscomaster Dynamic Viscosity Meter...
Test pressure Tested to 1.5 x the maximum operating pressure PED compliance Outside the scope of European directive 97/23/EC on Pressure Equipment. (1) Actual maximum operating pressures are limited by the process connection rating. Micro Motion 7829 Viscomaster Dynamic Viscosity Meter...
South Korean Register of Shipping South Korea General classifications Electromagnetic compatibility All versions conform to the latest international standards for EMC, and are compliant with EN 61326/IEC 61326. Environment • Weather rating: IP66 Micro Motion 7829 Viscomaster Dynamic Viscosity Meter...
3.9 or 20.8 mA on 4–20 mA System alarm 2 or 22 mA on 4–20 mA (Programmable alarm state) Communications RS-485 (Modbus) Electrical connection Screw terminal, cable entry to suit ½" NPT gland (20 mm adaptor available) Micro Motion 7829 Viscomaster Dynamic Viscosity Meter...
Certificates of material traceability (per single order) Typical model number: 7829FEANAHRABA (1) 4–20 mA output 2 default setting is temperature. (2) Compatible with DN80 XS pipework. (3) With a minimum wall thickness of 0.24 in (6 mm). Micro Motion 7829 Viscomaster Dynamic Viscosity Meter...