Jetter JetMove 200 Series User Information page 47

At the nano system bus
Table of Contents

Advertisement

JetMove 2xx at the NANO System Bus
See JetMove 2xx operator's manual
Meaning of the values:
0
1
Here, the operating mode is set, in which the controller is to be run.
Meaning of the values:
101
102
103
Jetter AG
Register 541: Operating mode of the 7-segment
Function
Read
Write
Value range
Value after reset
:
Normal operation
:
Installation
Register 572: Set operating mode
Function
Read
Write
Amplifier status
Validity
Value range
Value after reset
:
Current control (only the current control is active)
A set current value can be input via register 125
:
Speed control (current control and speed control are active)
A set speed value can be input via register 111
:
Position control (current control, speed control and position control
are active)
display
Description
Number of the actual operating mode
New number of the operating mode
0 ... 1
0
Description
Number of the presently set operating mode
Number of the newly set operating mode
The amplifier must be deactivated
When the amplifier is activated again
101, 102, 103
103
9.1 Control Parameters
47