SRP-X500P RS-232C Interface Manual
•
COMPRESSOR GAIN REDUCTION
Indicatess the gain reduction level reading of the COMPRESSOR (in dB units).
The parameter and the gain reduction level reading are shown in the following table.
GAIN
REDUCTION
More than 30
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
GAIN
REDUCTION
0x30 ('0')
15
0x31 ('1')
14
0x32 ('2')
13
0x33 ('3')
12
0x34 ('4')
11
0x35 ('5')
10
0x36 ('6')
9
0x37 ('7')
8
0x38 ('8')
7
0x39 ('9')
6
0x3A (':')
5
0x3B (';')
4
0x3C ('<')
3
0x3D ('=')
2
0x3E ('>')
1
0x3F ('?')
0
Page 38/43
0x40 ('@')
0x41 ('A')
0x42 ('B')
0x43 ('C')
0x44 ('D')
0x45 ('E')
0x46 ('F')
0x47 ('G')
0x48 ('H')
0x49 ('I')
0x4A ('J')
0x4B ('K')
0x4C ('L')
0x4D ('M')
0x4E ('N')
0x4F ('O')