♦ Parameter
The parameter consists of 16 bytes of data in the order shown in the following table.
Byte
Parameter
1st
MIC 1/WL 1 INPUT LEVEL METER
2nd
MIC 2/WL 2 INPUT LEVEL METER
3rd
MIC 3 INPUT LEVEL METER
4th
MIC 4 INPUT LEVEL METER
5th
LINE INPUT L LEVEL METER
6th
LINE INPUT R LEVEL METER
7th
AV/RGB INPUT L LEVEL METER
8th
AV/RGB INPUT R LEVEL METER
9th
SPEAKER OUTPUT 1 LEVEL METER
10th
SPEAKER OUTPUT 2 LEVEL METER
11th
SPEAKER OUTPUT 3 LEVEL METER
12th
SPEAKER OUTPUT 4 LEVEL METER
13th
LINE OUTPUT 1 LEVEL METER
14th
LINE OUTPUT 2 LEVEL METER
15th
LINE OUTPUT 3 LEVEL METER
16th
LINE OUTPUT 4 LEVEL METER
LEVEL METER (1st-16th byte)
Indicates the level meter reading (in VU units).
The parameter and the level meter reading are as shown in the following table.
Level meter
reading
Less than -30
-30
-20
-15
-10
-8
-7
-6
-5
SRP-X500P RS-232C Interface Manual
Level meter
reading
0x30 ('0')
-4
0x31 ('1')
-3
0x32 ('2')
-2
0x33 ('3')
-1
0x34 ('4')
0
0x35 ('5')
1
0x36 ('6')
2
0x37 ('7')
3 or more
0x38 ('8')
Page 22/43
0x39 ('9')
0x3A (':')
0x3B (';')
0x3C ('<')
0x3D ('=')
0x3E ('>')
0x3F ('?')
0x40 ('@')