9
Electrical system
9.4
Functions
78

Transformer/rectifier (EBL 119)

Do not cover the ventilation slots. Danger of overheating!
Depending on the model, not all slots for the fuses are occupied.
Deviating from the default assignment, the following fuse values are
inserted:
"Basic light / step": 20 A
"Reserve 3": 10 A (fuse for USB socket)
Further information can be obtained in the manufacturer's instruction
manual.
Fig. 68
Transformer/rectifier (EBL 119)
1
Main supply socket 240 V~
2
Output: Block 1 - refrigerator
3
Input: Block 2 - control lines
4
Output: Block 4 - heater, safety/drainage valve, basic light (lighting in the entrance
area), entrance step
5
Output: Block 3 - panel
6
Output: Block 5 - solar cell (if fitted), spare 2, spare 3, spare 4
7
Output: Block 6 - solar charge regulator (if fitted)
8
Output: Block 7 - auxiliary charging unit
9
Output: Block 8 - consumer circuit 1, consumer circuit 2, 12 V socket, water pump,
spare 1, spare 5, spare 6
10 Battery selector switch (lead-gel/AGM)
11 Fuses
12 Battery cut-off switch ("Batterie Ein/Aus" (battery On/Off))
The transformer/rectifier has the following functions:
The transformer/rectifier charges the living area battery. The transformer/
rectifier charges the starter battery with a float charge only.
The transformer/rectifier monitors the voltage in the living area battery.
The transformer/rectifier distributes the current to the 12 V circuits and
secures them. Devices with a maximum of 10 A can be connected to the
sockets.
The transformer/rectifier provides connections for a solar charge regulator,
an auxiliary charging unit, as well as other control and monitoring functions.