The C-2 Relay Valve functions to reproduce in
substantial volume whatever pressure is applied to the
small volume control portion of the valve itself. Its
essential purpose is to increase the speed of operation
for devices such as brakes, clutches, positioning
devices and to reduce trans-mission time in control
lines. This valve is usually directed by a relatively small
pressure control valve, such as a CONTROLAIR
Valve, which is located at some distance from the
controlled volume and is connected by small diameter
pipe or tubing.
WARNING: INSTALLATION AND
MOUNTING
The user of these devices must conform to all applicable
electrical, mechanical, piping and other codes in the
installation, operation or repair of these devices.
INSTALLATION! Do not attempt to install, operate or repair
these devices without proper training in the technique of
working on pneumatic or hydraulic systems and devices,
unless under trained supervision.
Compressed air and hydraulic systems contain high levels of
stored energy. Do not attempt to connect, disconnect or
repair these products when a system is under pressure.
Always exhaust or drain the pressure from a system before
performing any service work. Failure to do so can result in
serious personal injury.
MOUNTING! Devices should be mounted and positioned in
such a manner that they cannot be accidentally operated.
INSTALLATION
Two 9/16 holes are provided on the pipe bracket for
mounting of the valve. Suitable clearance should be
allowed to permit removal of the valve portion from the
pipe bracket for servicing without disturbing the piping.
Ports for air connections are numbered on the pipe
bracket and the sizes are as follows:
1 - Supply, 1/2" - 14 NPT
2 - Control, 1/4" - 18 NPT
3 - Delivery, 1/2" - 14 NPT
EX- Exhaust, 3/4" - 14 NPT
SM-400.8002
C-2 RELAY VALVE
SERVICE INFORMATION
The supply pressure should not exceed a
®
MAINTENANCE
C-2 Relay Valve should be visually inspected for
wear
performance and leakage test at least once a
year. If these visual observations indicate valve
repair is required, the valve must be removed,
repaired and tested.
C-2 Relay Valve should be dismantled at periodic
intervals for inspection, cleaning and lubrication.
A major overhaul is recommended at one million
cycles. However, where frequency of use is such
that is would require more than two years to
obtain one million cycles, the valve must be
overhauled at the two year period.
After disassembly, clean all metal parts with a
nonflammable solvent.
blow dry with a low pressure air jet. Replace all
rubber parts and those parts which are damaged,
corroded, or worn.
The diaphragm and rubber packing rings should
be carefully inspected and replaced if cracked or
worn.
During re-assembly, lubricate all rubber parts
except diaphragm with Dow Corning 55 M
Grease and all metal-to-metal surfaces with
Number 107 Lubriplate.
ADJUSTMENT
The C-2 Relay Valve requires no adjustment.
maximum of 250 psi. The control pressure
normally should not exceed 150 psi.
For additional dimensional information, ask for
drawing ID-76233-1.
and
given
an
"in
system"
operating
Rinse thoroughly and

Advertisement

loading

Summary of Contents for Aventics C-2

  • Page 1 C-2 RELAY VALVE SERVICE INFORMATION The C-2 Relay Valve functions to reproduce in substantial volume whatever pressure is applied to the small volume control portion of the valve itself. Its essential purpose is to increase the speed of operation The supply pressure should not exceed a for devices such as brakes, clutches, positioning maximum of 250 psi.
  • Page 2 Legend 1—Supply 2—Control 3—Delivery Ex-Exhaust 3 25/32” 7 ¼” Fig. 2 Outline View Page 2...
  • Page 3: Repair Parts List

    New Part Ref. SEE KIT SEE KIT 26* RING, 15/16” O.D. Ex.V. Seal Number Housing Packing -538975-00000 R431000091 C-2 RELAY VALVE, complete SEE KIT SEE KIT 27* SPRING, Exhaust Valve -850012-00000 R431000110 RELAY VALVE PORTION complete SEE KIT SEE KIT 28* RING, 1-5/8”...
  • Page 4 From the foregoing it will be seen that the cause movement downward repeating C-2 Relay Valve will reproduce in the delivery application cycle and restoring the delivery line a pressure equal to that in the control line pressure to the desired value. will...
  • Page 5 No charge will be made for labor with respect to defects covered by this Warranty, provided that the work is done by AVENTICS or any of its authorized service facilities.
  • Page 6 . cam/ ca i r1Fa-.c:a@a¥eJTtic.s.com Slv1-4QQ.8QQ2/May 2QT4 Sub1ec:ttn c:hange. Printed in Unite.ct States. AVENTICS Carparatian This dac:urnent. as well as the data. spe:c:ific:atians. and athe:rinfurmatian setfurth in it are the ED\Clusive property at AVEl",JTlCS. It may natb.e reproduced ar given ta third parties without its can sent...

This manual is also suitable for:

R431000091R431000110