Download Print this page

Secure Beanbag Manual page 2

Advertisement

Advance Mode
Add device
(1)
Remove device
(1)
Activate Learn mode
Enter listening mode
Broadcast device
Information
Check
signal
strength
(2)
Factory reset
Associate Channel
(1)
Remove channel
association
(2)
View associated
channel ID
(2)
Change fuel type
(2)
View fuel type
(2)
Lock/unlock
temperature set point
Role transfer
(1)
Exit
(3)
1.
Maximum time out for activity is 55 seconds.
2.
Operation applicable if node available in association group 2.
SUPPORTED DEVICE AND COMMAND CLASSES
Z-Wave Device Classes
Generic
Specific
Basic
Command Classes
Supported
Manufacturer Specific
Version
(V2)
Device Locally reset
Z-Wave Plus Info
(v2)
Include any Z-Wave device into its network
Exclude any Z-Wave device from network
Start Learn process for inclusion / Exclusion from other network
(1)
Listen mode for sending Wakeup Notification to wake up node if configured
(1)
Broadcast its Node Information Frame (NIF)
RF signal strength test using power level CC with associated node in Group 2
Outcome
3 bars
2 bars
1 bar
Perform protocol reset, set thermostat configurations to factory default.
Please use this procedure only when the network primary
Note:
controller is missing or otherwise inoperable.
Associate node in group 2 by Classic / Multichannel association, using NIF /
Multichannel capability report from other Z-Wave device (node).
Remove associated node from association group 2
Display associated end point (Channel number ) in association group 2
Display Text
None
CH x
Used to Set / Change boiler fuel type to configure TPI cycle.
View present boiler fuel type.
Disable / Enable set-point change using Up/Down buttons.
Shift primary role to the new controller in network
Exit from advance mode
Implemented Device Class
Multilevel Sensor
Routing_Sensor_Multilevel
Portable Controller
Description
Secure Controls (UK) Manufacturer ID, Device serial number
(V2)
Provides the version number of the firmware, hardware and supported
Command Classes.
Used to inform lifeline node that the device has been factory reset, and is
(v1)
leaving the network.
Z-Wave Plus Version 1
Role Type - ROLE_TYPE_CONTROLLER_PORTABLE_REPORTING
Function Description
Network Health
Action on associated node
Good
No action
Acceptable
May move node, or install repeater node in-between
Insufficient
Must move node, or install repeater node in-between
Description
No End point available in association group
End point x ( 1 to 127 ) available in association group
2