Permitted Forces And Torques On The Flanges For Combiblochorti - Johnson Pump SPX Flow CombiLine Series Instruction Manual

Centrifugal pumps
Table of Contents

Advertisement

CombiLine-CombiBlocHorti
10.8
Horizontal Pump, End branch, x-Axis
CBH
Fy
80C-200 1050 945 1173 1838 438 508 613 910 718 875 788 1383 403 455 560 823
80-250
1050 945 1173 1838 438 508 613 910 718 875 788 1383 403 455 560 823
100-160 1243 1120 1383 2170 525 665 735 1068 945 1173 1050 1838 438 508 613 910
100C-200 1243 1120 1383 2170 525 665 735 1068 945 1173 1050 1838 438 508 613 910
100C-250 1243 1120 1383 2170 525 665 735 1068 945 1173 1050 1838 438 508 613 910
125-250 1575 1418 1750 2748 613 718 875 1278 1120 1383 1243 2170 525 665 735 1068
150-125 1575 1418 1750 2748 613 718 875 1278 1418 1750 1575 2748 613 718 875 1278
150-160 1575 1418 1750 2748 613 718 875 1278 1418 1750 1575 2748 613 718 875 1278
150-200 1575 1418 1750 2748 613 718 875 1278 1418 1750 1575 2748 613 718 875 1278
150-250 2100 1890 2345 3658 805 928 1138 1680 1418 1750 1575 2748 613 718 875 1278
200-200 2100 1890 2345 3658 805 928 1138 1680 1890 2345 2100 3658 805 928 1138 1680
250-200 2980 2700 3340 5220 1260 1460 1780 2620 2700 3340 2980 5220 1260 1460 1780 2620
CL-CBH/EN (1901) 7.6

Permitted forces and torques on the flanges for CombiBlocHorti

Forces and moments acting on the pump flanges due to pipe loads can cause
misalignment of the pump, deformation and overstressing of the pump casing, or
overstressing of the fixing bolts between the pump and the baseplate.
The values can be applied simultaneously in all directions with positive or negative signs,
or separately on each flange (suction and discharge).
Figure 26:
Coordinate system.
Table 8: Permitted forces and torques on the flanges.
Force [N]
Moment [N.m]
Σ
Fz
Fx
My
F
Technical data
Z
Y
Z
Pump unit rigid mounted
Horizontal Pump, Top branch, z-Axis
Force [N]
Σ
Mz
Mx
Fy
Fz
M
X
Y
X
Moment [N.m]
Σ
Fx
My
Mz
F
Σ
Mx
M
69