Heat Pump; Solar - Nibe HA-WH5 F Installer Manual

Indirectly heated domestic hot water cylinders for heat pumps and other energy sources
Table of Contents

Advertisement

Solar connections
Connecting to solar power, heat pump or external heat source
The solar heating system's supply and return are connected to the HA - WH5 FS.
Primary return.
T&P valve

Heat Pump.

Ø22mm
Install the pipe for the T&P valve as illustrated on page 9.
Solar connections
Primary flow.
Connecting to solar power and heat pump

Solar.

Ø22mm
The solar heating system's supply and return are connected to the Titanium Megacoil- Solar Coil.
Primary flow
Heat Pump.
Ø22mm
7
Heat pump connections
Connecting to heat pump or another external heat source
The heat pump supply and return are connected to HA - WH5 F.
Heat pump connections
Connecting to heat pump
The heat pump supply and return are connected to Titanium Megacoil.
Primary flow.
Heat Pump.
Ø22mm
Secondary return.
1/2" F
(Except 160 litre)
12
Chapter 4 |
Pipe connections
12
Chapter 4 |
Pipe connections
137,5
137,5
Immersion
heater.
97,2
6
B
137,5 137,5
97,2
6
3/4" F. Cold inlet.
A
Temp. sensor
Hot outlet
BT 6
Ø22mm
1/2" F
Thermostat and
temp limiter
immersion heater.
Primary return.
Solar.
Ø22mm
7
Temp. sensor
BT 7
1/2" F
5
3/4" F. Cold inlet.
Hot outlet
Ø22mm
Primary return.
Heat Pump.
Ø22mm
Temp. sensor
BT 7
1/2" F
5
4
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ha-wh5 fs

Table of Contents