Parameterization
4.1 Function block _ET200S_FC_control
Parameter description
The following table contains all the parameters of the function block _ET200S_FC_control.
Table 4-1
Parameters of the FB _ET200S_FC_control
Name
Type
Data type
1)
execute
IN
BOOL
mode
IN
enum_ET200S_
FC_mode
(READ, WRITE,
DATA1, DATA2,
RESET_ERR)
periIn
IN
ARRAY [0 to 7]
of BYTE
setpoint
IN
DINT
ctrlDword
IN
DWORD
paraNumber
IN
UINT
subIndex
IN
UINT
paraValueWr IN
REAL
done
OUT
BOOL
busy
OUT
BOOL
error
OUT
BOOL
errorID
OUT
WORD
driveError
OUT
BOOL
driveErrorId
OUT
UINT
periOut
OUT
ARRAY [0 to 7]
of BYTE
actValue
OUT
DINT
statusDword
OUT
DWORD
paraValueRd OUT
REAL
Parameter types: IN = input parameter, OUT = output parameter
1)
See the
2)
See the
3)
18
Default
FALSE
READ
8 (16#00)
0
16#00000000 Control words (STW 1 and STW 2) of the ET 200S FC, transferred
0
0
0.0
FALSE
FALSE
FALSE
16#0000
FALSE
0
8 (16#00)
0
16#00000000 Status words (ZSW 1 and ZSW 2) of the ET 200S FC
0.0
SIMATIC ET 200S FC Frequency Converter Parameter Manual (03/2005 Edition).
SIMATIC ET 200S FC Frequency Converter Operating Instructions (03/2005 Edition).
Meaning
Start of a data transfer from/to the ET 200S FC with rising edge
Selection of data transfer type
● READ: Read individual parameter
● WRITE: Write individual parameter
● DATA1: Data set 1 is set active (p0810 to 0.0) with rising edge
on parameter execute.
● DATA2: Data set 2 is set active (p0810 to 1.0) with rising edge
on parameter execute.
● RESET_ERR: Acknowledgement of parameterization and
drive errors
Transfer I/O inputs of ET 200S FC to FB
Normalized setpoint without units for the ET 200S FC, transferred
cyclically
4)
cyclically
5)
Parameter number to be read or written
Index of an indexed parameter for the ET 200S FC
Parameter value to be written
TRUE = Read/write parameter was processed without errors
TRUE = Read/write parameter active
TRUE = parameterization error
Error number of the parameterization error (error number 0..108,
or 16#0000..16#006C)
3)
Note: If error = TRUE and errorID = 16#0000, the following error
is pending: "Invalid parameter number"
TRUE = Drive error is pending (refer to the driveErrorId parameter)
Reason for the error (decimal format)
Value corresponds to parameter r0947 (errors)
Prepared FB data for I/O outputs of the ET 200S FC
Display of the parameter value of p2051.1 (process data on field
bus)
2)
Read parameter value
Supplement for the ET 200S frequency converter
2)
2)
Function Manual, 01/2015