There are 3 levels of failures:
1. Level 1 will flash and the generator will
run. There may be a slight impact on per-
formance.
2. Level 2 will flash and the generator will
shut down if multiple errors are detected.
3. Level 3 will shut down the generator.
Fault
Code
2
TPS Failure
3
Cylinder Temp. Failure
4
Temp. Failure
5
System Voltage Low
6
System Voltage High
7
Cylinder High Temp.
8
Barometric Pressure Sensor
Failure
9
Oil Pressure Anomaly
11
Fuel Injector Failure
13
Fuel Pump Failure
15
Ignition Failure
17
ECU Internal Failure
18
Crankshaft Position Sensor
Failure
19
ECU Reset
22
Engine Overspeed Failure
24
Load Stability Sensor Failure (On-1.2s, Off-0.5s) Repeat 1X, (On-0.25s, Off-0.5s)
27
Stepper Motor Stuck
28
Engine Starting Failure
Low Battery
Owner's Manual for Portable Generator
Fault Code
Fault Flash (Seconds)
On-0.25s, Off-0.5s, On-0.25s
On-0.25s, Off-0.5s Repeat 2X
On-0.25s, Off-0.5s Repeat 3X
On-0.25s, Off-0.5s Repeat 4X
On-0.25s, Off-0.5s Repeat 5X
On-0.25s, Off-0.5s Repeat 6X
On-0.25s, Off-0.5s Repeat 7X
On-0.25s, Off-0.5s Repeat 8X
On-1.2s, Off-0.5s, On-0.25s
On-1.2s, Off-0.5s,(On-0.25s, Off-0.5s) Repeat 2X
On-1.2s, Off-0.5s,(On-0.25s, Off-0.5s) Repeat 4X
On-1.2s, Off-0.5s,(On-0.25s, Off-0.5s) Repeat 6X
On-1.2s, Off-0.5s,(On-0.25s, Off-0.5s) Repeat 7X
On-1.2s, Off-0.5s,(On-0.25s, Off-0.5s) Repeat 8X
(On-1.2s, Off-0.5s) Repeat 1X, (On-0.25s, Off-0.5s)
Repeat 1X
Repeat 3X
(On-1.2s, Off-0.5s) Repeat 1X, (On-0.25s, Off-0.5s)
Repeat 6X
(On-1.2s, Off-0.5s) Repeat 1X, (On-0.25s, Off-0.5s)
Repeat 7X
On-0.2s, Off-0.2s