Invacare® Comet Series
4. Install parts in reverse order.
5. Use setting screw (3) to set spring hardness.
6. Test all functions (trial run).
5.8.3 Replacing swing arm
•
14 mm wrench
•
5 mm Allen key
1. Remove rear shroud.
2. Remove motor and differential gear. See chapter
4.10.1 Replacing drive unit, page 28.
3. Remove batteries. See user manual.
4.
Loosen and remove screw A that attaches swing arm
to chassis on left and right side of the mobility device.
5.
Loosen and remove lower bolt B on rear shock
absorber on left and right side of mobility device.
24
Be careful not to loose metal bushing A in swing
arm B.
6. Remove and replace swing arm.
7.
Install parts in reverse order.
When reinstalling, tighten screw A to 15 Nm.
5.8.4 Replacing steering column
CAUTION!
Risk of accident
Accidental rolling can lead to accidents.
– Secure mobility device against rolling away.
When disassembling, note the position of small
parts such as screws and washers. Put small parts
down so that they can be reassembled in the right
sequence.
•
10 mm wrench
•
13 mm wrench
•
17 mm wrench
•
19 mm wrench
•
32 mm wrench
•
Phillips screwdriver
•
Supporting wooden block
1. Remove seat.
2. Remove shroud.
1603798-D