Quick Reference Guide
The Tissue-Tek Prisma
an instrument that simultaneously carries out multiple
staining protocols on slides containing sections that are
acquired from fresh or fixated material. The instrument,
as part of the histopathology process, is intended to
Ensure
facilitate the in vitro examination of human and animal
tissue for morphology changes by a pathologist.
This Quick Reference Guide contains information about
day-to-day use, maintenance and cleaning. For more
detailed information we refer to the most recent
Operating Manual of this instrument.
All users should be trained for the use of the Sakura
instruments. The Sakura User Training is a training to
ensure that new and existing users of a Sakura
instrument have the knowledge and skills to operate and
maintain the instrument in a proper way.
Daily operations
To operate the instrument start with entering the
password on the touch screen display.
Note: Ensure that the reagents within the instrument
match the current or desired configuration before
starting a program.
The door at the bottom of the hood gives access to the
start stations. While loading these pay attention to the
orientation of the basket, the "upside" should face right.
The instrument can be loaded with two types of baskets
containing either 10 or 20 slides.
The starting procedure explained below is an example.
If the instrument has been set to start upon closing of
the door, you do not need to touch the start key. By
pressing the Start key in the main screen a menu
appears from where the staining protocol, the location of
the basket, number of slides and coverslipper program
are selected. The last two options will only appear when
certain user defined settings are met.
®
Plus
®
Plus automated slide stainer is
Version : 2019-1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Tissue-Tek Prisma Plus and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sakura Tissue-Tek Prisma Plus

  • Page 1 Operating Manual of this instrument. All users should be trained for the use of the Sakura instruments. The Sakura User Training is a training to ensure that new and existing users of a Sakura instrument have the knowledge and skills to operate and maintain the instrument in a proper way.
  • Page 2 Multiple runs with an identical program are started at the same time by selecting more than one start station. Pressing Start again will start the selected staining protocol. During process the permitted operations are limited. In continuous mode the option to add more baskets and start them with priority becomes available.
  • Page 3 Preventative maintenance Cleaning touch screen Preventative maintenance is performed by a Sakura representative or a qualified service Use a cloth moistened with 70-80% alcohol to engineer. clean the screen. Do not directly spray on the screen as this may cause damage.
  • Page 4 Maintenance task Frequency Exterior surface Daily Interior surface Daily Washing stations Daily Drain Daily Solution reservoirs Weekly Touch screen Weekly Slide baskets and holder Weekly Replace carbon filters Bi-weekly Drying and heating stations Monthly Preventative maintenance Yearly  The use of bleach or acid might cause corrosion.