Specifications
SPECIFICATIONS
Voltage
Display
Operating Temperature
Storage Temperature
Dimensions
Weight
Pulse and Relays
Pulse Electrical
Relay Electrical
Pulse/Unit Volume
(Totalizer)
Set-Point (Alarm)
Analog Output
USB Communication
RS485 Communication
Accessories
Flow Sensor Inputs
Type
Threshold
Pulse-Di
2 .5V DC
Pulse-K Factor
2 .5V DC
Pullup K Factor
2 .5V DC
Sine-K Factor
Analog - 4...20 mA
Analog - 0...20 mA
Analog - 0...1V DC
Analog - 0...5V DC
Analog - 0...10V DC
Rate Units of Measure: GPM; gal/sec; gal/hr; Mgal/day; LPS; LPM; LPH; ft
m
/min; m
/hr; acre-ft/sec; acre-ft/min; acre-ft/hr; bbl/sec; bbl/min; bbl/hr; and field programmed custom units 0 .00 to 999999999
3
3
Total Units: gallons; Mgal; liters; ft
Page 30
12...24V DC/AC (limit: 8...35V DC); (limit: 8...28V AC)
16 character by two line alphanumeric Dot Matrix 3/8 in . (7 .95 mm) high backlit LCD
–4...158° F (–20...70° C)
–22...176° F (–30...80° C)
Panel Mount: 3 .78 in . W × 3 .78 in . H × 4 .79 in . D (96 mm × 96 mm × 122 mm)
Panel Mount: 12 oz .
Both pulse and relay are fully functional as either totalizing or setpoint outputs
1 Amp at 35V DC/30V AC
Resistive Load:
5A @ 120V AC/30V DC
Driving SourceE: flow total
Driving SourceE: flow rate,
Btu rate, temperature 1,
temperature 2, delta T
Delay to Set: 1 to 9999 sec
Driving Source: flow rate
Provides complete access to all programming and
operation features
Supports Modbus and BACnet/MSTP
Programming kit
Signal Limit
30V DC
0 .4 Hz to 10 kHz
30V DC
0 .4 Hz to 10 kHz
30V DC
0 .4 Hz to 10 kHz
—
30V DC
0 .4 Hz to 10 kHz
—
50 mA Fused
—
50 mA Fused
—
30V DC
—
30V DC
—
30V DC
; m
; acre-ft; bbl; and field programmed custom units 0 .00 to 999999999
3
3
Closed: 0 .5 Ω at 1 amp; Open: >10
Inductive Load:
1A @ 120V AC/30V DC
RateE: 1 pulse per 1 .0000000 to
99999999 units
Units: Any predefined or custom
unit
Release Point: 1 .0000000 to
999999999
Range: 4...20 mA; 0...20 mA
(isolated current sinking or sourcing)
Frequency
Pullup
1K to 12V DC
—
1K to 12V DC
—
—
—
—
—
—
—
—
—
—
—
CTL-UM-01026-EN-05
DC current draw (~ 280 mA)
AC Power rating (~5 VA)
Ω
8
Contact TimeE: 1 to 9999 mS
Set-Point: 1 .0000000 to 999999999
Delay to Release: 1 to 9999 sec
Sinking: 30V DS @ 0 mA max;
3 V @ 20 mA min
Sourcing: 600 Ω max load
Requirements: USB 2 .0 A to Mini-B,
five-pin cable
Impedance
Aux. Power
—
12V DC@30 mA
—
12V DC@30 mA
—
12V DC@30 mA
10K Ω
12V DC@30 mA
100 Ω
12V DC@30 mA
100 Ω
12V DC@30 mA
100K Ω
12V DC@30 mA
100K Ω
12V DC@30 mA
100K Ω
12V DC@30 mA
/Sec; ft
/min; ft
/hr;m
/sec;
3
3
3
3
Calibration
K + Offset
Pulse/Gal
Pulse/Gal
Pulse/Gal
Linear
Linear
Linear
Linear
Linear
October 2017