Specifications
SPECIFICATIONS
Power Supply Options
Battery Powered
Loop Powered
Alphanumeric Oate and Total Display
Eight digit, 0�75 inch high numeric display
Eight character, 0�38 inch high alphanumeric display
Fixed or toggle modes of operation for flow rate and totalizer display
Accuracy
Temperature Drift
Mounting Classification
Meter Mount
Remote Mount
Swivel Mount
Environmental
Operating Temperature
Humidity
Inputs
Magnetic Pickup Input
Outputs
Type
Maximum Voltage
Pulse Width
Current (ON state)
Optional
Certifications
CSA
CE
Page 16
One D size, 1�5V alkaline battery
Optional 4...20 mA loop power
±0�1%
50 ppm /° C (maximum)
Type 4X enclosure
Type 4X enclosure
Type 4X enclosure
–22...158° F (–30...70° C)
0...90% non-condensing
Frequency Range: 0...3500 Hz
Trigger Sensitivity: 30 mV p-p
Over Voltage Protected: ±30V DC
Opto-isolated open collector transistor
30V DC
20 mS/maximum rate 20 Hz
0�9V drop @ 5�0 mA or 0�7V drop @ 0�1 mA
4...20 mA output
Class I, Div 1 Groups C, D; Class II, Div 1 Groups E, F, G; CSA C22�2
No� 157-92, UL 913
IEC 61326-1
DSY-PM-00276-EN-04
March 2017