TECHNICAL DATASHEET
PMT Panel Mount Power Supply
48V 350W 1 Phase / PMT-48V350W1A

Engineering Data

Output Load De-rating VS Surrounding Air Temperature
Fig. 1
De-rating for Vertical and Horizontal Mounting Orientation
> 50°C de-rate power by 2.5% / °C
Output De-rating VS. Input Voltage
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
8
www.DeltaPSU.com (November 2018, Rev. 04)
□□
Note
1.
Power supply components may degrade, or
be damaged, when the power supply is
continuously used outside the shaded region,
refer to the graph shown in Fig. 1.
2.
If the output capacity is not reduced when the
surrounding air temperature exceeds its
specification as defined on Page 3 under
"Environment", the device will run into Over
Temperature Protection. When activated, the
output voltage will go into bouncing mode and
will
recover
when
temperature is lowered or the load is reduced
as far as necessary to keep the device in
working condition.
3.
In order for the device to function in the
manner intended, it is also necessary to keep
a safety distance of ≥ 20mm
adjacent units while the device is in operation.
4.
Depending on the surrounding air temperature
and output load delivered by the power
supply, the device can be very hot!
5.
If the device has to be mounted in any other
orientation,
info@deltapsu.com for more details.
No output power de-rating for the input
voltage from 100Vac to 132Vac & 200Vac to
264Vac
■ L Frame / Enclosed
the
surrounding
air
(0.78 inch)
with
please
contact