Fujitsu PRIMERGY BX600 S3 Hardware Manual page 14

Blade server system unit
Hide thumbs Also See for PRIMERGY BX600 S3:
Table of Contents

Advertisement

Chapter 1 Component Names and Functions
1 9 DC Power LED
It lights depending on the status of the DC power of the
PSU as follows.
There is no DC power LED in the dummy PSU.
LED status
ON (Green)
Operating normally.
OFF
DC power is not supplied to each
Server Blade. When this LED is OFF
while AC power is supplied and the
main power of the Chassis is on,
there is an error in the PSU. Contact
an office listed in the "Contact
Information" of "Start Guide" or
device administrator.
2 0 Warning LED
It lights depending on the status of the PSU as follows.
LED status
ON (Amber)
There is an error in the PSU. Contact
an office listed in the "Contact
Information" of "Start Guide" or
device administrator.
OFF
Operating normally.
2 1 AC Power LED
Lights or blinks depending on the status of the AC
power of the PSU as follows.
There is no AC power LED in the dummy PSU.
LED status
ON (Green)
AC power is supplied to the PSU.
OFF
AC power is not supplied.
2 2 System fan module LED
The LED is lit in green when a fan module is installed in
the system fan unit. The upper LED is for fan module 1
and the lower LED is for fan module 2.
2 3 System fan module error LED
The LED is lit in amber when an error is detected in the
fan module installed in the system fan unit. The upper
LED is for fan module 1 and the lower LED is for fan
module 2.
2 4 Management Blade master LED
It lights depending on the Management Blade operation
status as follows.
LED status
ON (Green)
Operating in master mode
OFF
Operating in slave mode
14
Server Status
Server Status
Server Status
Server Status
2 5 Management Blade error LED
It lights or blinks when a Management Blade error
occurs as follows. If this LED lights or blinks, contact
an office listed in the "Contact Information" of "Start
Guide" or device administrator.
LED status
ON (Amber)
A Management Blade error has
occurred (non redundant
Management Blade configuration).
Blinking
A Management Blade error has
occurred (redundant Management
(Amber)
Blade configuration).
OFF
Operating normally.
2 6 10BASE-T/100BASE-TX connector (
An Unshielded Twisted Pair (UTP) cable is plugged in.
2 7 Serial port connector (9- pin) (
Connect using an RS-232C cross cable.
2 8 LAN active LED
Blinks depending on the status of the Management
Blade LAN transfer as follows. Also it may blink
uniformly when NIC diagnostic function of the
Management Blade is used.
LED status
Blinking
Data is being transferred.
(Amber)
2 9 LAN link LED
Lights depending on the connection status of the
Management Blade LAN as follows.
LED status
ON (Green)
LAN link is being established.
Server Status
)
)
Server Status
Server Status

Advertisement

Table of Contents
loading

Table of Contents