Sequency timing:
Parameter Number
15 ( SEQUENCY_TIME )
Time in [100 miliseconds] of maximum delay between BASIC ON and BASIC
OFF (and vice versa) to relay endpoint to consider this as a sequence. It is
typically 1 second, but can be exceptionally longer due to retransmissions and
overload – in this case, a longer interval can be allowed (up to 5 seconds).
Motion Off behaviour (timeout):
Parameter Number
16 (MOTION_DISABLE)
Motion disable timeout after BASIC SET to motion endpoint when the internal
motion sensor is not used for evaluating the behaviour of the relay and groups
2 and 3. Events are, however, still transmitted to the Lifeline, and the relay can
be controlled via remote motion sensors.
BASIC SET to Motion sensor endpoint ignored, BASIC to root is
0
mapped to relay endpoint, motion sensor still enabled
Internal motion sensor is disabled for specified timeout after BASIC
SET 0x00 to Mootion sensor endpoint. BASIC to root is mapped to
Motion sensor endpoint.
1 -209
Timeout:
1..100 – 1 second (1) to 100 seconds (100) in 1-second resolution
101..200 – 1 minute (101) to 100 minutes (200) in 1-minute resolution
201..209 – 1 hour (201) to 9 hours (209) in 1-hour resolution
210-254
Reserve
BASIC SET to Motion sensor endpoint ignored, BASIC to root is
255
mapped to relay endpoint, motion sensor still disabled
Size
Range
Default
1
10 – 50
10
Size
Range
Default
2
0 – 209, 255
- 56 -
0