2. Enable the receipt of the time from the required time transmitter.
– From NTP server
– From local station
– Receive time from WAN
4.13

SMSC

SMSC
If the CP (firmware V3) is intended to use the sending of SMS messages, you need to
activate the option here. Configure the number of the SMSC being used (Short Message
Service Center).
For configuring the parameters for the CP with firmware V2.1 refer to the section
Configuration of the serial interface (Page 79).
4.14

Subscriber numbers

Subscriber numbers
Here you assign the subscriber numbers of the CPU and the CP.
● Subscriber number
The subscriber number is unique for every subscriber in an ST7 network.
For the meaning of the subscriber numbers, see section ST7 (Page 61).
– CPU subscriber number
– CP subscriber number
For the application of the master station PC, the subscriber number is configured in the
telecontrol connection: Editor "Network data" > "Telecontrol" tab
You configure WAN address of the CP in the parameter group "WAN parameters", see
section WAN parameters (networking the CP) (Page 82).
CP 1243-8 IRC
Operating Instructions, 02/2018, C79000-G8976-C385-03
(only when telecontrol communication is disabled)
(adoption of the time from the local CPU)
If the CP is connected to a classic WAN network and time-of-day synchronization is
enabled in the network, the CP automatically takes the time from the WAN network
with the settings made there. The parameter is then activated on the CP and the
parameter group is grayed out.
Subscriber number of the local CPU of the station
Subscriber number of the CP
Configuration