1.4 Plumbing

1.4.a Plumbing Requirements
NOTICE
Do not use glue on the threaded portion of the equipment's unions. A glued-in-place union will prevent the
l
equipment from being properly winterized.
The chiller must receive water flow within the specified minimum ranges under worst-case conditions such as a
l
fouled water filter.
Failure to provide clean filtered water to the chiller can void product warranty.
l
Water flow exceeding maximum flow rates will negatively affect the total pool filtration performance and may
l
damage the chiller. This will not be covered under equipment warranty. See "Water Flow Rates" on page 9.
Install a bypass valve whenever water-flow may exceed maximum rating.
l
See "Bypass Valve Kit (# STK0135)" on page 26.
l
For additional guidance testing water flow rates, please contact AquaCal
l
1.4.b Plumbing Diagrams
Plumbing diagrams are provided in this section as a planning guide to the sequence of equipment, valves, and
fittings.
The basic plumbing configurations for typical installations are shown.
l
If the installation does not closely follow any of the supplied plumbing diagrams, AquaCal
l
available for installation advice and guidance.
Confirm water provided to chiller is clean and filtered.
l
Chiller with water flows equal or less than maximum listed flow rate
See "Water Flow Rates" on page 9.