SECTION 2 - INSTALLATION
For commercial or complete installation instructions please, visit www.AquaCal.com for equipment manual.
EQUIPMENT CLEARANCES
Keep the area immediately adjacent to the water chiller clear of items such as shrubs and bushes, lawn furniture,
chemicals containers, etc. These items can prevent air from circulating properly through the water chiller, and will
result in inefficient operation and/or damage.
Overhang with
Gutter
Rain Run-Off and
Sprinklers Should Be
Directed Away From
water chiller
(Front)
30" Minimum
Clearance
PLUMBING SCHEMATIC
F
WC
B
ELECTRICAL REQUIREMENTS
Locate the equipment power disconnect within 6-feet of the water chiller's electrical enclosure.
1)
2)
Never mount power disconnects directly to water chiller.
3)
Only use copper conductors.
4)
Local codes and regulations may require the use of a ground fault interruption device (GFI Circuit Breaker).
Nuisance tripping of these devices is common and not covered under the terms of the Manufacturer's warranty.
5)
Review online product manual when connecting external controller devices to water chiller.
5 feet Minimum Clearance
Overhead
(Rear)
12" Clearance
P
D
3
S
POOL
R
C
Figure 3
(Side)
12"
Figure 1
3
= Three-Way Valve
B
= Bypass Check Valve (5lb) for Water Flow
Over Max Flow (see
details)
C
= Chlorinator
D
= Main Drain
F
= Filter
WC
= Water Chiller
P
= Water Pump
R
= Return
S
= Skimmer
Page 2
(Rear)
12"
(Side)
12"
(Front)
30"
Figure 2
Specifications
for