safety regulations
hazard: hazardouS vaporS
Paints, solvents, insecticides, and other materials
can be harmful if inhaled or come in contact with
body. Vapors can cause severe nausea, fainting,
or poisoning.
prevention:
Use a respirator or mask if vapors can be inhaled. Read
all instructions supplied with the mask to be sure it will
provide the necessary protection.
Wear protective eyewear.
Wear protective clothing as required by coating
manufacturer.
hazard: Skin burn injury
Heated parts can cause severe skin burn injury.
prevention:
Quick disconnect fittings on the hose and spray gun become
hot during use. Avoid skin contact with quick disconnect
fittings when they are hot. Allow quick disconnect fittings
to cool before disconnecting the spray gun from the hose.
hazard: exploSion or fire
Solvent and paint fumes can explode or ignite.
Severe injury and/or property damage can occur.
prevention:
Provide extensive exhaust and fresh air introduction to
keep the air within the spray area free from accumulation
of flammable vapors.
Avoid all ignition sources such as static electricity sparks,
electrical appliances, flames, pilot lights, hot objects, and
sparks from connecting and disconnecting power cords or
working light switches.
Plastic can cause static sparks. Never hang plastic to
enclose spray area. Do not use plastic drop cloths when
spraying flammable materials.
Do not smoke in spray area.
Fire extinguisher must be present and in good working
order.
4
Power cord must be connected to a grounded circuit
(electric units only).
Follow material and solvent manufacturer's warnings and
instructions. Be familiar with the coating material's MSDS
sheet and technical information to ensure safe use.
Use extreme caution when using materials with a flashpoint
below 70° F (21º C). Flashpoint is the temperature that a
fluid can produce enough vapors to ignite.
The object to be coated must be earthed.
Before working on the device, remove the power plug from
the socket.
1.3
electric Safety
Electric models must be grounded/earthed.
of an electrical short circuit, grounding/earthing reduces
the risk of electric shock by providing an escape wire for the
electric current. This product is equipped with a cord having
an grounding/earthing wire with an appropriate grounding/
earthing plug. Connection to the power cord only through a
special feed point, e.g. through an error protection insallation
with INF < 30 mA.
DANGER — Work or repairs at the electrical
equipment may only be carried out by a skilled
electrician. No liability is assumed for incorrect
installation. Switch the unit off. Before all repair
work, unplug the power plug from the outlet.
Danger of short-circuits caused by water
ingressing into the electrical equipment. Never
spray down the unit with high-pressure or high-
pressure steam cleaners.
Caution – The power cord for this equipment
acts as an supply circuit connector. The power
cord must be placed near an easily accessible,
unobstructed socket-outlet.
fc9900 Plus
In the event

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fc9900 plus

Table of Contents