Actual signals and parameters

About this chapter

This chapter describes the actual signals and user-adjustable parameters of the MPPT
function specific to the solar pump inverter. Refer these parameters in addition to the
actual signals and parameters described in the ACS355 User's manual
(3AUA0000066143 [English]).

Actual signals

Actual signals
No.
Name/Value
01 OPERATING DATA
0182
PUMP RUN HOUR
0183
CALCULATED FLOW
0184
TODAY FLOW
Description
Basic signals for monitoring the solar pump
inverter (read-only). The inverter sets the values
based on measurements or calculations.
Shows the actual run time of the pump in hours.
Note: You can reset the counter to zero when the
control panel is in parameter mode. Non-zero
values are not accepted.
To reset the counter, press the
keys simultaneously.
Shows the calculated flow rate of water in cubic
meter per hour. The calculation is based on the
correction factor defined in
GAIN.
Shows the measured flow of current day in cubic
meter.
Note: You can reset this value using
FLOW.
Actual signals and parameters 37
7
UP/DOWN
6124 FLOW CAL
6131 RESET
FbEq
1 = 1 h
100 =
1 m³/h
10 = 1 m³